Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images

Authors

  • Farahnaz Rahimi M.Sc. Student, Department of Medical Radiation Engineering, Shahid Beheshti University, G.C. Tehran, Iran, [email protected]
Abstract:

Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable clinical results due to inability in true tumor volume delineation and uncertainty in dose calculation of treatment planning software. So far, no generally accepted solution to this problem, especially for small size dental fillings, has been found. Herein, an approach is presented to reduce the dental filling artifacts in CT images of head and neck patients with multiple dental fillings. The proposed approach is compared with the commercial orthopedic metal artifact reduction (O-MAR) algorithm by Philips company. Materials and Methods: Our algorithm consists of six steps: 1) metallic object segmentation by thresholding, 2) obtaining the prior image by multi thresholding of the initial image, 3) normalization of the original image sinogram by prior image, 4) interpolation (replacing the affected projection data by previous slice unaffected projection data, 5) denormalization of the corrected sinogram and 6) application of a two dimensional adaptive filter to the final image. The forth step can be implemented by substitution of affected projections with opposite view projections. Both methods were tested and previous slice substitution was superior. Quantitative evaluation of the commercial and proposed algorithms was done in terms of peak signal-to-noise ratio (PSNR), signal-to- noise ratio (SNR) and structural similarity index (SSIM) on a CT image of a head and neck patient with four dental fillings. The posterior part of the head in original image was considered as the reference image. Also two uniform regions of interest (ROI) were considered in the image. ROI1 was posterior region of the head away from dental fillings, while ROI2 was restricted to the tongue region near to the dental fillings. Results: The PSNR, SNR, SSIM values obtained by the proposed method and O-MAR algorithm were 37.05, 36.13, 22.29, 21.37, 0.93 and 0.84, respectively. Using our approach, the standard deviation of CT numbers in ROI1 was 27 times less than the original image and 7% better than the commercial competitor. However, for ROI2 the commercial algorithm was 36% more successful in reduction of variations due to metal artifact. Conclusion: The proposed approach can be applied successfully for dental filling artifact reduction in head and neck patients. Although the performance of the commercial method was superior to ours in near dental regions, for the farther regions with more critical organs was vice versa. However, weighting the interpolation and adaptive filtering steps may result in even better results.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

A New Method for Metal Artifact Reduction in CT Scan Images

Introduction In CT imaging, metallic implants inside the tissues cause metal artifact that reduce the quality of image for diagnosis. In order to reduce the effect of this artifact, a new method with more appropriate results has been presented in this research work. Materials and Methods The presented method comprised of following steps: a) image enhancement and metal areas extraction, b) sinog...

full text

Metal artifact reduction in dental CT images using polar mathematical morphology

Most dental implant planning systems use a 3D representation of the CT scan of the patient under study as it provides a more intuitive view of the human jaw. The presence of metallic objects in human jaws, such as amalgam or gold fillings, provokes several artifacts like streaking and beam hardening which makes the reconstruction process difficult. In order to reduce these artifacts, several me...

full text

CT Dental Artifact: Comparison of an Iterative Metal Artifact Reduction Technique with Weighted Filtered Back-Projection

Background Dental hardware produces streak artifacts on computed tomography (CT) images reconstructed with the standard weighted filtered back projection (wFBP) method. Purpose To perform a preliminary evaluation of an iterative metal artifact reduction (IMAR) technique to assess its ability to improve anatomic visualization over wFBP in patients with dental amalgam or other hardware. Mater...

full text

a new method for metal artifact reduction in ct scan images

introduction in ct imaging, metallic implants inside the tissues cause metal artifact that reduce the quality of image for diagnosis. in order to reduce the effect of this artifact, a new method with more appropriate results has been presented in this research work. materials and methods the presented method comprised of following steps: a) image enhancement and metal areas extraction, b) sinog...

full text

Thyroid dose and dose reduction method from CT scan of head and neck

Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and i...

full text

Segmentation of artifacts and anatomy in CT metal artifact reduction.

PURPOSE Metal objects present in x-ray computed tomography (CT) scans are accompanied by physical phenomena that render CT projections inconsistent with the linear assumption made for analytical reconstruction. The inconsistencies create artifacts in reconstructed images. Metal artifact reduction algorithms replace the inconsistent projection data passing through metals with estimates of the tr...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  447- 447

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023