Measurement and comparison of head scatter factor for 9MV photon beam using the build-up cap and a columnar mini-phantom
Authors
Abstract:
Introduction: The Sc is an important parameter to monitor unit (MU) calculation in radiation therapy procedure. The aim of this study is to measurement and comparison of head scatter factor (Sc) for 9MV photon beam using the build-up cap and a columnar mini-phantom. Materials and Methods: The measurements performed using a calibrated ion chamber (Scanditronix / Wellhofer Farmer Type Chamber FC65-G), and electrometer (Scanditronix / Wellhofer, Dose 1 Reference class electrometer). Sc’s values were measured on Neptun linear accelerator. The Sc measured in the source to surface distance (SSD) of 100cm in different square field sizes (5×5 to 38×38 cm) using two available devices: the PMMA build- up cap and dmax dose water equivalent columnar mini-phantom. Results: Sc’s values for 5×5, 10×10, 15×15, 20×20, 25×25, 30×30, 35×35 and 38×38 cm2 field sized with columnar mini-phantom were 0.97, 1, 1.02, 1.04, 1.06, 1.07, 1.08, and 1.09, respectively. Sc’s values for 5×5, 10×10, 15×15, 20×20, 25×25, 30×30, 35×35 and 38×38 cm2 field sized with build-up cap were 0.96, 1, 1.03, 1.06, 1.08, 1.09, 1.10, and 1.11, respectively. Conclusion: Though measured Sc value using build-up cap in 5×5 cm2 field size was smaller than of those Sc measured using columnar mini-phantom, higher values result in larger field sizes than 10×10 cm2.
similar resources
Off-axis primary-dose measurements using a mini-phantom.
The characterization of the incident photon beam is usually divided into its dependence on collimator setting (head-scatter factor) and off-axis position (primary off-axis ratio). These parameters are normally measured "in air" with a build-up cap thick enough to generate full dose build-up at the depth of dose maximum. In order to prevent any influence from contaminating electrons, it has been...
full textthe innovation of a statistical model to estimate dependable rainfall (dr) and develop it for determination and classification of drought and wet years of iran
آب حاصل از بارش منبع تأمین نیازهای بی شمار جانداران به ویژه انسان است و هرگونه کاهش در کم و کیف آن مستقیماً حیات موجودات زنده را تحت تأثیر منفی قرار می دهد. نوسان سال به سال بارش از ویژگی های اساسی و بسیار مهم بارش های سالانه ایران محسوب می شود که آثار زیان بار آن در تمام عرصه های اقتصادی، اجتماعی و حتی سیاسی- امنیتی به نحوی منعکس می شود. چون میزان آب ناشی از بارش یکی از مولفه های اصلی برنامه ...
15 صفحه اولCalculation the phantom scatter factor for the linear accelerators device
Introduction: In the last few decades, a lot of monte carlo codes have been introduced for medical applications. this is important because through simulation, we are fully independent of the spectral scattering factor that we are not able measure in real terms. The effect of the radiation energy, the dimension of the radiation field, the sensitive volume of the ion chamber on t...
full textInterpretation of In-air Output Ratio of Wedged Fields in Different Measurement Conditions
Introduction: The head scatter factor (Sc) is one of the important parameters for monitor unit (MU) calculation. There are multiple factors that impact the Sc values, such as, head structures, back scattering in to dose monitoring chambers, wedges and so on. This study aimed to investigate the variations of SC with different build-up cap materials, wall thickness, Source to ...
full texta comparison of teachers and supervisors, with respect to teacher efficacy and reflection
supervisors play an undeniable role in training teachers, before starting their professional experience by preparing them, at the initial years of their teaching by checking their work within the proper framework, and later on during their teaching by assessing their progress. but surprisingly, exploring their attributes, professional demands, and qualifications has remained a neglected theme i...
15 صفحه اولAn Analytical Method to Calculate Phantom Scatter Factor for Photon Beam Accelerators
INTRODUCTION One of the important input factors in the commissioning of the radiotherapy treatment planning systems is the phantom scatter factor (Sp) which requires the same collimator opening for all radiation fields. In this study, we have proposed an analytical method to overcome this issue. METHODS The measurements were performed using Siemens Primus Plus with photon energy 6 MV for fiel...
full textMy Resources
Journal title
volume 15 issue Special Issue-12th. Iranian Congress of Medical Physics
pages 238- 238
publication date 2018-12-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023