Mean Activity Coefficients Measurements and Thermodynamic Modeling of the Ternary Mixed Electrolyte KCl + Lactose + Water System at T = 298.15 K

Authors

  • Mohammad Ali Bagherinia Department of Chemistry, Faculty of Science, Lahijan Branch, Islamic Azad University, Lahijan, Iran
  • Nazanin Zahra Norouzi Department of Chemistry, Faculty of Science, Lahijan Branch, Islamic Azad University, Lahijan, Iran
Abstract:

In this work, the mean activity coefficients of KCl in the KCl+lactose +water system were determined using the potentiometric method. The electromotive force measurements were carried out on the galvanic cell without liquid junction of the type: Ag|AgCl|KCl (m), lactose (wt.%), H2O (1−wt.) %|K-ISE, in various mixed solvent systems containing 0, 5,7.5, 10 and 12.5 % mass fractions of lactose. The ionic strengths range was from 0.0003 to 2.000 kg.mol−1. The modeling of this ternary system was made based on the Pitzer ion-interaction model. The mean activity coefficients were correlated with Pitzer model and the adjustable Pitzer parameters (βo, β1 and Cø) were determined for the series under investigated system. Then, these parameters were used to calculate the amounts of thermodynamic properties such as osmotic coefficients and excess Gibbs free energies for under investigated systems. The results clearly indicated that a good correlation was obtained with the Pitzer model to describe this system.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Thermodynamic Study of the Ternary Electrolyte (1-Butyl-3-methylimidazolium chloride + sodium chloride + Water) System Using Potentiometric Measurements

In this paper, the thermodynamic properties of the aqueous mixed electrolyte system containing 1-butyl-3-methylimidazolium chloride ([BMIm]Cl) and NaCl are reported based on the potentiometric method. The potentiometric measurements were performed on the galvanic cells without liquid junction of the type:Ag-AgCl [BMIm]Cl (m1), NaCl(m2), H2O│IL-...

full text

Construction of Cu2+-selective electrode and thermodynamic study of the ternary aqueous mixed electrolyte system (CuCl2, KCl, H2O) using nanocomposite-based potentiometric sensor

A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...

full text

Construction of Cu2+-selective electrode and thermodynamic study of the ternary aqueous mixed electrolyte system (CuCl2, KCl, H2O) using nanocomposite-based potentiometric sensor

A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...

full text

Determination and Modeling the Activity Coefficients of 1-Propyl-3- methylimidazolium Bromide in the Ethanol + Water Mixtures at T = (298.2, 308.2 and 318.2) K

In this work, the results relating to the mean activity coefficient measurements for ionic liquid of 1- propyl -3 methylimidazolium bromide, [PMIm]Br in ethanol+ water mixtures have been reported using potentiometric measurements at T=( 298.2, 308.2 and 318.2)K. The electromotive force (emf) measurements were performed on the galvanic cell of the type:Br-ISE│[PrMIm] (m) ethanol (wt.%), H2O (1−w...

full text

thermodynamic study of the ternary electrolyte (1-butyl-3-methylimidazolium chloride + sodium chloride + water) system using potentiometric measurements

in this paper, the thermodynamic properties of the aqueous mixed electrolyte system containing 1-butyl-3-methylimidazolium chloride ([bmim]cl) and nacl are reported based on the potentiometric method. the potentiometric measurements were performed on the galvanic cells without liquid junction of the type:ag-agcl [bmim]cl (m1), nacl(m2), h2o│il-ise, over total ionic strengths from 0.0025 to 2.00...

full text

construction of cu2+-selective electrode and thermodynamic study of the ternary aqueous mixed electrolyte system (cucl2, kcl, h2o) using nanocomposite-based potentiometric sensor

a nanocomposite membrane cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (etmoc) as a neutral ionophore. the electrode works properly. it responds to cu2+ ion with a sensitivity of 29.5 ± 0.2 mv/decade over the range 1.0 × 10−9 to 5.0 × 10−1m at ph 3.0-8.0. the limit of detection was 4.5 × ...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 5  issue 4

pages  783- 794

publication date 2017-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023