Local Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran

Authors

  • Mohammad Taghi BahreyniToossi Medical Physics Research Center, Medical Physics Department, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
Abstract:

Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an area or an institution as a Local DRL (LDRL). Materials and Methods To establish DRL for diagnostic X-ray examinations of children in KhorasanRazavi province, data were collected from 627 pediatric patients. The average of entrance surface doses (ESDs), arising from chest and abdomen examinations, were examined for three different age groups. Results Local DRL (LDRL) were calculated to be 77, 126, and 138 µGy for chest examinations of

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

local diagnostic reference levels for common pediatric x-ray examinations in khorasan razavi province, iran

introduction given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. diagnostic reference level (drl) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...

full text

Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran

Introduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiologic examination in Sabzevar county. Materials and Methods: There are eight radiology departments ...

full text

Diagnostic reference levels (DRLs) for routine X-ray examinations in Lorestan province, Iran

Background: In diagnostic radiology there are two reasons for measuring or estimating radiation doses to patients. Firstly measurements provide a means for setting and checking standards of good practice as an aid to the optimization of patient protection. Secondly estimates of the absorbed dose to tissue and organs in the patients. Materials and Methods: A total of 2382 patients were studied t...

full text

diagnostic reference levels (drls) for routine x-ray examinations in lorestan province, iran

background: in diagnostic radiology there are two reasons for measuring or estimating radiation doses to patients. firstly measurements provide a means for setting and checking standards of good practice as an aid to the optimization of patient protection. secondly estimates of the absorbed dose to tissue and organs in the patients. materials and methods: a total of 2382 patients were studied t...

full text

Diagnostic reference levels for X-ray examinations in Slovenia

Background. Medical applications of ionizing radiation are by far the largest man-made source of radiation exposure for the population in most developed countries. A good practice in diagnostic radiology should produce an image containing all necessary information needed for accurate diagnosis and should result in the minimum dose to the patient. After introduction of diagnostic reference level...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 11  issue 4

pages  301- 307

publication date 2014-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023