Local Diagnostic Reference Levels for Common Computed Tomography Procedures at a Tertiary Hospital in South Africa
Authors
Abstract:
Introduction: An operational computed tomography (CT) scanner is a major source of human exposure to ionizing radiation. Exposure increases the risk of cancer and aplastic anaemia. All radiation exposures should be justified and optimized to meet the clinical objective. In order to avoid the administration of excessive radiation dose to patients, diagnostic reference levels (DRLs) were proposed. The DRLs identify unusually high radiation doses during CT procedures, which are not commensurate with the clinical objective. They have been successfully implemented in Europe, United States, some developed countries, and a few developing countries. In this regard, the present study aimed at establishing DRLs for the head, chest, and abdomen/pelvis CT procedures at a tertiary hospital in South Africa. Material and Methods: A retrospective analysis of volume CT dose index (CTDIvol) and dose length product (DLP) was performed on 100 randomly selected adult patients for each of the head, chest, and abdomen/pelvis CT procedures. The mean values of the DLP and CTDIvol dose parameters were calculated using SPSS, version 24. Results: The established DRLs for CTDIvol were 32; 7, and 32 mGy for the head, abdomen/pelvis, and chest, respectively, while the DLPs for the respective protocols were 767, 386, and 593 mGy.cm. Conclusion: The implementation of DRLs facilitates identifying CT doses that are not commensurate with the clinical objective, thereby lowering patients’ doses significantly.
similar resources
Establishment of Diagnostic Reference Levels and Estimation of Effective Dose from Computed Tomography Head Scans at a Tertiary Hospital in South Africa
Introduction: Head scans are the most frequently performed computed tomography (CT) examinations worldwide. However, there is growing concern over the probability of increased cancer risks among the exposed populations. Diagnostic reference levels (DRLs) identify radiation dose that is not commensurate with clinical objectives. The aim of this study was to establish DR...
full textA local study on diagnostic reference levels estimation for children computed tomography
Introduction: The Diagnostic reference levels (DRLs) play a critical role in the optimization of radiation dose especially, in some conditions like pediatrics. They are useful indicators by which the radiologists can be aware of delivered excess radiation doses to the patients, and take corrective actions if necessary. In order to meet some requirements for establishing the nat...
full textDose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...
full textEstimation of diagnostic reference levels for children computed tomography: A study in Tehran, Iran
Background: The Diagnostic reference levels (DRLs) play a critical role in the optimization of radiation dose especially, in some conditions like pediatrics. They are useful indicators by which the radiologists can be aware of delivered excess radiation doses to the patients, and take corrective actions if necessary. In order to meet some requirements for establishing the national computed tomo...
full textDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
full textLocal Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran
Introduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiologic examination in Sabzevar county. Materials and Methods: There are eight radiology departments ...
full textMy Resources
Journal title
volume 16 issue 5
pages 349- 354
publication date 2019-09-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023