Ion Selective Carbon Paste Electrode For The Determination Of Flavoxate Muscle Relaxant Drug In Pharmaceutical Formulation

author

Abstract:

Abstract The utility of carbon paste electrode for the determination of flavoxate HCl modified with flavoxate-tetraphenylborate (FLX-TPB) and flavoxate-phosphotungestic acid (FLX-PTA) ion-pairs in batch mode is demonstrated. The electrodes revealed a Nernstian response over a wide concentration ranges 1.39×10-5-1x10-2 mol L-1 and1×10-5-1x10-2 mol L-1 using FLX-TPB and FLX-PTA, respectively. The detection limits of these sensors are 1.39×10-5 mol L-1, and 1x10-6 mol L-1 using FLX-TPB and FLX-PTA, respectively. The best performance was obtained with carbon paste composition of 5% flavoxate-tetraphenylborate or flavoxate-phosphotungestate, 47.5% graphite and 47.5% o- nitro phenyl octyl ether (o-NPOE). The sensors exhibit a very fast response time (5-7 s) and good selectivity in presence of inorganic cations, sugars and aminoacids. The proposed sensors show great improvement in comparison with other previously reported sensors. The sensors were successfully applied to monitoring of flavoxate in pure solution and pharmaceutical formulation (Genurin tablet) with recovery ranges from 97.2 – 101.0% and 98.1-101.6% using FLX-TPB and FLX-PTA, respectively.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

ion selective carbon paste electrode for the determination of flavoxate muscle relaxant drug in pharmaceutical formulation

abstract the utility of carbon paste electrode for the determination of flavoxate hcl modified with flavoxate-tetraphenylborate (flx-tpb) and flavoxate-phosphotungestic acid (flx-pta) ion-pairs in batch mode is demonstrated. the electrodes revealed a nernstian response over a wide concentration ranges 1.39×10-5-1x10-2 mol l-1 and1×10-5-1x10-2 mol l-1 using flx-tpb and flx-pta, respectively. the...

full text

Ion Selective PVC Membrane Electrode for the Determination of Methacycline Hydrochloride in Pharmaceutical Formulation

A plastic membrane electrode for the determination of methacycline hydrochloride was fabricated based on the use of methacycline-tetraphenylborate as the electroactive substance, and dioctylphtalate as the plasticizing agent. It was found that the potential responses of the electrode were influenced by pH of the tested solution when pH>3. Under the condition of pH 2.6, the linear response range...

full text

A Novel Carbon Paste Electrode for Potentiometric Determination of Vanadyl Ion

Carbon paste electrode was modified by disodium 2,4-diamino-7-methylbenzo[g] pteridine-5,10-dioxide to fabricate a sensor for potentiometric determination of vanadyl ion (VO2+) in aqueous medium. The new ligand was synthesized in three steps with high yield. The optimal composition of the carbon paste was made of graphite powder (64.5%), ionophore (16.6%), paraffin oil (17.8%), a...

full text

application and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples

ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...

15 صفحه اول

Liquid Chromatographic Determination of Flavoxate HCl in Pharmaceutical Formulation

The objective of the study was to develop a high performance liquid chromatography (HPLC) method using ultra violet (UV) detection for the determination of flavoxate HCl in bulk and solid dosage forms by using ibuprofen as the internal standard. Eclipse C18 column (150 mm × 4.6 mm, 5 μm) was used as the stationary phase with a mixture of acetonitrile : 0.1% formic acid in water (75: 25 v/v) as ...

full text

Selective Electrochemical Nanosensor based on Modified Carbon Paste Electrode for Determination of NADH in the presence of Uric Acid

The electrochemical properties of a modified carbon paste electrode with the synthesized compound of 2,2'-[1,7–heptanediylbis(nitrilomethylidene)]-bis(4-hydroxyphenol) (DHBH) and graphite nanoparticle (GN) were studied by cyclic voltammetry (CV), chronoamperometry and differential pulse voltammetry (DPV) methods. The proposed electrode shows excellent electrocatalytic activity towards the oxida...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 12  issue 1

pages  45- 58

publication date 2016-01-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023