Investigation of neutron flux by thermoluminescence dosimeters in the neutron-gamma mixed field

Authors

  • Peyvand Taherparvar Department of physics, University of Guilan, Rasht. Iran. [email protected]
Abstract:

Introduction: Neutrons have many applications in various fields, such as medicine. The important application of neutron in medical science is in Boron Neutron Capture Therapy (BNCT). Because of this, determination of neutron dose and flux is critical for the health maintaining of workers and patients exposed to this beam. The neutron radioisotope sources produce gamma rays in addition to the neutrons, and the neutron fields around these sources are mixed-field neutron-gamma fields. Since the separation of the dose of each radiation component in the compound field is difficult, the gamma-neutron mixed field dosimetry is a major challenge. International Commission on Radiation and Units (ICRU) recommends the use of a dosimeter pair for mixed-field dosimetry that have different responses to each component of radiation. One of the effective methods of neutron dosimetry is the use of the TLD-600/700 dosimeter pair. TLD-600 is 6Li enriched and TLD-700 is 7Li enriched. These dosimeters have the same sensitivity to gamma radiations but TLD-600 is sensitive to thermal neutrons because of high capture cross-section of 6Li, while in low fluxes, TLD-700 has no sensitivity to thermal neutrons.   Materials and Methods: In this paper, in order to measure the neutron flux of the Ra-Be source in the core laboratory of the Faculty of Science of the University of Guilan. Six TLD-600/700 dosimeters were used in three intervals of 7, 14 and 20 cm from the source   Results: After 24 hours of irradiation, the intensity of the thermoluminescence of TLDs was measured by TLD reader. Finally, by calculating the calibration coefficient, the measured flux values by the TLDs were determined and compared with the calculated fluxes Conclusion: Results show that the measured and calculated values are in good agreement.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

An investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy

Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...

full text

Dosimetry in Mixed Neutron-Gamma Fields

The gamma field accompanying neutrons may, in certain circumstances, play an important role in the analysis of neutron dosimetry and even in the interpretation of radiation induced steel embrittlement. At the figh Flux Isotope Reactor pressure vessel the gamma-induced reactions dominate the responses of ' W p and 238u dosimeters, and9Be helium accumulation fluence monitors. The gamma induced at...

full text

Design and manufacture of composite flexible shield for neutron-gamma mixed fields

In this study, a flexible composite shield with a combination of polyethylene, tungsten and boron carbide has been designed and constructed for neutron-gamma mixed fields. For this purpose, theoretical studies were conducted using the multi-purpose MCNPX Code. According to the results of simulation studies, a multi-purpose composite was constructed using a combination of a solid phase of boron ...

full text

اندازه‌گیری دز گامای ایجاد شده توسط نوترون‌های حرارتی در دزسنج‌TLD-700

Neutron response Induced in Thermoluminescence Dosimeter TLD-700 chips due to reactions of thermal neutrons with slab phantom and Badge Dosimeter TLD-600,700 materials in a neutron-gamma mixed field was measured. Using the linear relationship between thermal neutron fluence and the thermal neutrons induced TL response with slab phantom, Badge-TLD Materials, an empirical relationship was introdu...

full text

an investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy

background: the aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or pmma), a150 plastic and te- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. materials and methods: thermal neutron fluence, photon dose and epithermal neut...

full text

Modeling the measurement of VVER-1000 reactor power by neutron and gamma radiation with MCNP code

The present study deals with a new method for measuring the power of a reactor. This method uses gamma and neutron radiation resulted from the entire reactor structure, without changing its structure (online). In terms of functionality, this method can measure the reactor power in real-time and report it instantly. In order to obtain the relationship between reactor power and gamma and neutron ...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  304- 304

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023