Investigating and Mathematical Correlation of the Presence Effect of Solute and Surfactant on Mean Drop size in a Mixer-Settler

Authors

Abstract:

In this paper, the effects of several factors such as surfactant concentration, solute concentration, impeller speed and holdup on the mean drop diameter ( ) during emulsification have been studied in a single-stage mixer-settler extractor. A video technique has been developed in order to measure drop size distribution in the mixing chamber using a digital camera. The results show decreases with an increase in solute concentration. decreases significantly in low concentrations of surfactant, while in general, droplet diameter decrease with surfactant concentration. Though it maybe negligible. Three correlations are derived: without solute and surfactant, with solute, and with surfactant. These correlations showed a good agreement with experimental data and Hinze-Kolmogorov theory has been well proved by all of them. The experimental results in the first case were compared with Godfrey’s model and it has a minor deviation from Godfrey’s model. For the second and the last case, there weren’t any models or experimental data to compare with. In fact, the last two cases were investigated for the first time.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

investigating and mathematical correlation of the presence effect of solute and surfactant on mean drop size in a mixer-settler

in this paper, the effects of several factors such as surfactant concentration, solute concentration, impeller speed and holdup on the mean drop diameter ( ) during emulsification have been studied in a single-stage mixer-settler extractor. a video technique has been developed in order to measure drop size distribution in the mixing chamber using a digital camera. the results show decreases wit...

full text

The Study of Corresponding Effects of anionic surfactant concentration and solute on Drop Size in a Mixer-Settler Extractor and Propose an Empirical Model

Drop size distribution in a mixer-settler is an essential design parameter, as obtaining drop size distribution will result in optimum performance of equipment. In this paper for obtaining drop size, several experiments have been performed with a single stage horizontal mixer-settler. A video technique has been used in order to measure the drop size in the mixer-settler with the help of a digit...

full text

the study of corresponding effects of anionic surfactant concentration and solute on drop size in a mixer-settler extractor and propose an empirical model

drop size distribution in a mixer-settler is an essential design parameter, as obtaining drop size distribution will result in optimum performance of equipment. in this paper for obtaining drop size, several experiments have been performed with a single stage horizontal mixer-settler. a video technique has been used in order to measure the drop size in the mixer-settler with the help of a digit...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 43  issue 1

pages  -

publication date 2009-10-01

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023