Inhibition of Human Erythrocyte Glucose 6-Phosphate Dehydrogenase by Cadmium, Nickel and Aluminium
Authors: not saved
Abstract:
This article doesn't have abstract
similar resources
inhibition of human erythrocyte glucose 6-phosphate dehydrogenase by cadmium, nickel and aluminium
0
full textINHIBITION OF HUMAN ERYTHROCYTE GLUCOSE 6-PHOSPHATE DEHYDROGENASE ACTIVITY BY DEHYDROEPIANDROSTERONE AND RELATED STEROIDS.
The inhibitory effects of several steroids on G6PD activity using intact erythrocytes are reported. Incubation of whole blood with dehydroepiandrosterone (DHEA) resulted in 42% and 12% inhibition in the enzyme activity in the presence and absence of oxygen, respectively. Addition of epinephrine and/or aminophylline into the incubation medium caused further enzyme inhibition suggesting a po...
full textinhibition of human erythrocyte glucose 6-phosphate dehydrogenase activity by dehydroepiandrosterone and related steroids.
the inhibitory effects of several steroids on g6pd activity using intact erythrocytes are reported. incubation of whole blood with dehydroepiandrosterone (dhea) resulted in 42% and 12% inhibition in the enzyme activity in the presence and absence of oxygen, respectively. addition of epinephrine and/or aminophylline into the incubation medium caused further enzyme inhibition suggesting a possibl...
full textGenetic Variants of Human Erythrocyte Glucose-6-phosphate Dehydrogenase
The values of V,,,,, and K, for the three genetic variants A, B, and Aof erythrocyte glucose-&phosphate dehydrogenase have been determined at 10 different pH values in the range from 5.5 to 9.5, and at four different temperatures in the range from 18.5-40.0”. The log V,,,,, versus pH curve for each of the enzymes shows a monotonic increase between pH 5.5 and 7, and a plateau from pH 7.5 upwards...
full textincidence of erythrocyte glucose-6-phosphate- dehydrogenase deficiency
in a survey carried out to establish the incidence of erythrocyte glucose 6-phosphate-dehydrogenase deficiency, 738 professional blood donors of tehran were examined. the fluorescent spot technique was used for screening and qualitative determination of g-6-pd in erythrocytes. this technique was compared with other methods of g-6-pd enzyme assay and proved to be very reliable. qualitative enzy...
full textMy Resources
Journal title
volume 15 issue 4
pages -
publication date 2004-12-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023