Influence of artificial aging on the shear bond strength of zirconia-composite interfaces after pretreatment with new 10-MDP adhesive systems

Authors

  • M Eisenburger Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
  • M Stiesch Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
  • p.c pott Department of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
Abstract:

Introduction: This in-vitro study investigates the bond strength of different zirconia composites  with three different modern adhesive systems after artificial aging using thermocycling and water storage. Methods: A total of 90 specimens of zirconia (InCoris, Sirona, Germany, Bernsheim) were ground using a 165 µm grit rotating diamond disc. Thirty specimens were additionally treated with either Futurabond U “FBU” (VOCO GmbH), or Futurabond M+ “FBM” (VOCO GmbH) or Futurabond M+ in combination with the DCA activator “FBMD” (VOCO GmbH). One of the three different types of composites – BifixSE “BS”, BifixQM “BQ” or GrandioSO “G” (VOCO GmbH) – was bonded to the ten specimens of each group. All of the specimens underwent artificial aging using thermocycling between 5°C and 55°C for 5000 cycles followed by water storage for 100 days. Shear bond strength (SBS) was determined in a universal testing machine. The type of failure was evaluated using fluorescence microscopy. The data were compared to existing data without artificial aging. Statistical analysis was performed with ANOVA and the Tukey test. Results: FBM and FBMD had higher SBS than FBU in combination with all tested composites, except BifixSE. In nearly all groups, artificial aging had no effect, with the exception of the combination of FBMD with BifixSE, in which there was a significant decrease in SBS after the aging process (p

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Influence of 10-MDP Adhesive System on Shear Bond Strength of Zirconia-Composite Interfaces

  Introduction: This in-vitro study investigated the initial 24h bond strength between different composites and zirconia after application of four different adhesive systems. Methods: A total of 120 specimens of zirconia (InCoris, Sirona, Germany, Bernsheim) were ground with a 165 µm grit rotating diamond disc. Thirty specimens were each additionally treated with Cimara Zircon “CZ” (VOCO GmbH, ...

full text

Influence of artificial aging on the shear bond strength of zirconia- composite interfaces after pretreatment with new 10-MDP adhesive systems

Introduction: This in-vitro study investigates the bond strength of different zirconia composites with three different modern adhesive systems after artificial aging using thermocycling and water storage. Methods: A total of 90 specimens of zirconia (InCoris, Sirona, Germany, Bernsheim) were ground using a 165 μm grit rotating diamond disc. Thirty specimens were additionally treated with either...

full text

Effect of Chlorhexidine on Micro-Shear Bond Strength of Two Adhesive Systems After Aging

Background and Aim: Recurrent caries and low bond strength are the main causes of composite restorations failure. This study sought to assess the effect of chlorhexidine (CHX) on micro-shear bond strength (MSBS) to dentin of a fourth generation adhesive system and a universal bonding agent after aging. Materials and Methods: This in vitro study used 32 extracted third molars and 3-5mm thick de...

full text

Micro-Raman Vibrational Identification of 10-MDP Bond to Zirconia and Shear Bond Strength Analysis

So far, there is no report regarding the micro-Raman vibrational fingerprint of the bonds between 10-methacryloyloxy-decyl dihydrogen phosphate (10-MDP) and zirconia ceramics. Thus, the aim of this study was to identify the Raman vibrational peaks related to the bonds of 10-MDP with zirconia, as well as the influence on microshear bond strength. Micro-Raman spectroscopy was employed to assess t...

full text

The influence of rotating fatigue on the bond strength of zirconia-composite interfaces.

OBJECTIVES To evaluate the effect of cyclic loading on the bond strength of resin composite to zirconia framework material. METHODS Bar shaped zirconia/composite specimens (2 mm x 2 mm x 25 mm) were prepared using three different resin cements and placed in a four-point bending test setup. The flexure strength (F(s)) was calculated by placing the bars (n=10) fixed between the four supports (a...

full text

Effect of salivary contamination on shear bond strength of three different dentin adhesive systems

Effect of salivary contamination on shear bond strength of three different dentin adhesive systems Dr. H. Kermanshah* - Dr. H. Haj miragha** - Dr. SH. Gatoeizadeh*** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Tehran University / Medical Sciences. **- Assistant Professor of Fixed Prosthodontics Dept. & Dental Research Center - Faculty of Dentistry – Tehran Unive...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 5  issue 1

pages  1- 10

publication date 2016-03-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023