Background and Aim:Root canal preparation with rotary instruments may cause dentinal cracks leading to tooth fracture. The aim of this study was to compare three different rotary systems ProTaper, RaCe and Niti Tee on formation of dentinal cracks following root canal preparation. Materials and Methods: In this experimental study, 50 extracted mandibular first molars were selected. Teeth having roots with previous cracks and defects were excluded from the study. The crowns and distal roots of teeth were cut. Silicon impression material was used to simulate tooth PDL. The mesial roots were randomly prepared using ProTaper (up to F3) RaCe and Niti Tee systems (up to ≠30/0.06) in three groups of 15. Five teeth remained unprepared as the control group. The specimens were then sectioned horizontally in 3, 5 and 9 mm distances from the apex. Cracks exploration was done by digital stereomicroscope. The occurrence of dentinal cracks with different systems were statistically analyzed by chi-square test. Results: Dentinal defects were observed in 3 (20%), 4 (26.7%) and 2 (13.3) of root canals following the preparation with ProTaper, Niti Tee and RaCe files, respectively. Two of the 3 defects in protaper group were as complete crack. The overall incidence of crack among the rotary files was 20%. No significant differences were found in defect formation between the three rotary systems (P>0.05).  Conclusion: Under the condituion of this study Dentinal cracks were observed in all systems. The overall incidence of crack among the rotary files was 20%. Although more cracks were observed in NTiTee group, the differences were not significant.    

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Effects of ProTaper Universal, ProTaper Next, and HyFlex instruments on crack formation in dentin.

INTRODUCTION The aim of the present study was to investigate the incidence of cracks in root dentin after root canal preparation with ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland), HyFlex (Coltene-Whaledent, Allstetten, Switzerland), and ProTaper Universal (Dentsply Maillefer) rotary instruments. METHODS One-hundred mandibular premolars were selected. Twenty-five teeth were left...

full text

comparison of dentinal crack formation with reciproc, mtwo and protaper root canal preparation systems

conclusions regarding the study limitations, dentinal cracks were observed in all files and distances from the apex. although there was more crack incidence in protaper files, no significant differences were noted regarding the studied systems and sections from the apex. materials and methods in an experimental in vitro trial, 80 maxillary and mandibular first molars were selected and their cro...

full text

Cyclic Fatigue Resistance and Fractographic Analysis of Race and Protaper Rotary NiTi Instruments

INTRODUCTION This study investigated the fatigue and fracture modes of RaCe and ProTaper rotary instruments. MATERIALS AND METHODS Fatigue resistance was evaluated by rotating the files 30° or 60° and with 2 or 5mm radius of curvature. RaCe taper 06 size 25 and ProTaper F1 files (n=40) were used. The number of rotations to failure was analyzed by two-way ANOVA and independent sample t-test. F...

full text

cyclic fatigue resistance and fractographic analysis of race and protaper rotary niti instruments

introduction: this study investigated the fatigue and fracture modes of race and protaper rotary instruments. materials & methods: fatigue resistance was evaluated by rotating the files 30 ° or 60 ° and with 2 or 5mm radius of curvature. race taper 06 size 25 and protaper f1 files (n=40) were used. the number of rotations to failure was analyzed by two-way anova and independent sample     t-tes...

full text

Influence of a glide path on the dentinal crack formation of ProTaper Next system.

OBJECTIVES The aim was to evaluate dentinal crack formation after root canal preparation with ProTaper Next system (PTN) with and without a glide path. MATERIALS AND METHODS Forty-five mesial roots of mandibular first molars were selected. Fifteen teeth were left unprepared and served as controls. The experimental groups consist of mesiobuccal and mesiolingual root canals of remaining 30 teet...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 6  issue 4

pages  152- 158

publication date 2017-09-29

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023