Impacts of New Suggested Ferroresonance Limiter on the Stability Domain of Ferroresonance Modes in Power Transformers Considering Metal Oxide Surge Arrester Effect

Authors

Abstract:

this work studies the effect of neutral earth resistance on the controlling ferroresonance oscillation in the power transformer including MOV surge arrester. A simple case of ferroresonance circuit in a three phase transformer is used to show this phenomenon and the three-phase transformer core structures including nonlinear core losses are discussed. The effect of MOV surge arrester and neutral earth resistance on the onset of chaotic ferroresonance and controlling chaotic transient in a power transformer including nonlinear core losses has been studied. It is expected that these resistances generally cause into ferroresonance control. Simulation has been done on a power transformer rated 50 MVA, 635.1 kV with one open phase. The magnetization characteristic of the transformer is modelled by a single-value two-term polynomial with q=7, 11. The core losses are modelled by third order in terms of voltage. The simulation results reveal that connecting the MOV arrester and neutral resistance to the transformer, exhibits a great impact on ferroresonance over voltages. Copyright © 2009 Praise Worthy Prize S.r.l. - All rights reserved.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Effect of New Suggested Ferroresonance Limiter on the Stability Domain of Chaotic Ferroresonance in the Power Transformer with Linear Core Model

This paper studies the effect of new suggested ferroresonance limiter on controlling ferroresonance oscillations in the power transformer. It is expected that this limiter generally can control the ferroresonance. For studying these phenomena, at first ferroresonance is introduced and a general modeling approach is given. A simple case of ferroresonance in a three phase transformer is used to i...

full text

Ferroresonance Phenomenon in Power Transformers - Experimental Assessment

This paper reports on the results of recent research and development efforts to study and assess various impacts of ferroresonance phenomenon on operating performance of power transformers and to investigate ways to mitigate the effects of such phenomenon. Three-phase core-type transformers are used in the study. The results of the technical investigation and the associated ferroresonance exper...

full text

Ferroresonance in Power and Instrument Transformers

This chapter describes the fundamental concepts of ferroresonance phenomenon and analyzes its symptoms and the consequences in transformers and power systems. Due to its nonlinear nature, the ferroresonance phenomenon can result in multiple oscillating modes which can be characterized based on the concepts of the nonlinear dynamic systems, e.g., Poincare map. Among numerous system configuration...

full text

Ferroresonance Suppression in Voltage Transformers

Ferroresonance is a special case of disturbance that involves high levels of overvoltage and overcurrents distortion. This phenomenon can severely affect voltage transformers and its consequences can be catastrophic. This paper analyses different practical solutions against ferroresonance phenomenon in voltage transformers, highlighting the current development of ferroresonance detection techni...

full text

Ferroresonance suppression in power transformers using chaos theory

The main goal of this paper is the determination of the effect of the metal oxide varistor (MOV) on various ferroresonance modes including fundamental resonance, subharmonic and chaos mode which are generated in electrical power systems. Chaos theory is used for analyzing this effect. Also, the bifurcation, phase plan diagram and time domain simulation are used for this purpose. The proposed po...

full text

Ferroresonance in Low - Loss Distribution Transformers

—Field experience indicates that ferroresonance events occur more readily with low-loss distribution transformers, compared to distribution transformers with conventional loss levels. Extensive testing of a large number of transformers has shown a very strong and direct correlation between transformer core loss and the amount of capacitance needed to sustain a ferroresonant condition. A heurist...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 7  issue 4

pages  283- 291

publication date 2011-12

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com