Image quality assessment in digital radiography systems- A Pehamed FLUORAD A+D phantom study
Authors
Abstract:
Introduction: The use of digital radiography systems has become more common all around the world. Ideal situation in radiography is to maximize the image quality while minimizing the patient dose. The purpose of this study was to compare image quality and radiation dose in different digital radiography systems. Materials and Methods: Images of Pehamed FLUORAD A+D phantom in five different tube voltage (50, 60, 70, 75, 80kVp) and five tube current of (100, 250, 360, 400, 560mA) in four different digital radiography systems were obtained. Three images were acquired in each imaging parameters. Image quality parameters (contrast resolution (CR), spatial resolution(SR) and contrast noise ratio(CNR)) were measured for each image. The number of low contrast object as a scale of CR and the number of resolution lead bar pattern as SR were considered. CNR of each image was determined with imageJ software. Dose area product (DAP) which was displayed during acquisition of each image: was recorded. Results: Image quality parameters (CR, SR, and CNR) as well as DAP were significantly different between different digital systems. It was shown that all four quantities increased with increasing exposure parameters in all systems. At fixed CR of 4 and CNR of 25, DAP value obtained in SEDECAL system was lower than others (p≤0.05)(Fig. 9) and at fixed SR of 3.36(lp/mm), DAP values in SEDECAL and Applem- R302/A were lower than two other systems (p≤0.05). Conclusion: The results of this investigation can be taken into consideration in the selection and purchasing of new systems in order to preserve patients as well as radiographers from unnecessary dose consistent with the radiation protection principle ALARA.
similar resources
A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography
Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...
full textThe Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality
Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality. Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...
full textEvaluation of a quality control phantom for digital chest radiography
RATIONALE AND OBJECTIVES To examine the effectiveness and suitability of a quality control (QC) phantom for a routine QC program in digital radiography. MATERIALS AND METHODS The chest phantom consists of copper and aluminum cutouts arranged to resemble the appearance of a chest. Performance of the digital radiography (DR) system is evaluated using high and low contrast resolution objects pla...
full textDigital radiography image quality: image acquisition.
This article on digital radiography image acquisition is the first of two articles written as part of an intersociety effort to establish image quality standards for digital and computed radiography. The topic of the other paper is digital radiography image processing and display. The articles were developed collaboratively by the ACR, the American Association of Physicists in Medicine, and the...
full textOptimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations
IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization inv...
full textClinical Image Quality Assessment in Panoramic Radiography
Amaç: Bu çalışmada elde edilen panoramik radyografilerin kalitesinin değerlendirilmesi ve tanı için yetersiz görüntülere neden olan hataların tespiti amaçlanmıştır. Yöntem: Çalışmada Oral Diagnoz ve Radyoloji AD arşivlerinde yer alan 150 adet panoramik radyografi incelenmiştir (Morita Veraviewwopcs model 550 ,Kyoto-Japan, en yüksek KVP of 80, mA=12, monitör 17 inç TFT LCD, 100-240 VAC 60/50 Hz,...
full textMy Resources
Journal title
volume 15 issue Special Issue-12th. Iranian Congress of Medical Physics
pages 72- 72
publication date 2018-12-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023