High Performance Liquid Chromatography Determination of Sertraline in Human

Authors

  • Amir Farshchi School of Pharmacy, Kermanshah University of Medical Sciences, Kermanshah, Iran Department of Pharmocoeconomy and Pharmaceutical Management, Shcool of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
  • Gholamreza Bahrami School of Pharmacy, Kermanshah University of Medical Sciences, Kermanshah, Iran
  • Golbarg Ghiasi School of Pharmacy, Kermanshah University of Medical Sciences, Kermanshah, Iran Department of Pharmocoeconomy and Pharmaceutical Management, Shcool of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
Abstract:

       An accurate and sensitive reversed-phase high-performance liquid chromatograph-ic method for determination of sertraline in human serum is described using 4-chloro-7-nitrobenzofurazan as pre-column derivatization agent. The drug and an internal standard (azithrimycin) were extracted from serum using a mixture of diethyl ether-chloroform and subjected to the pre-column derivatization with the reagent. Analysis of the resulted derivatives was performed on a Lichrosorb CN (250×4.0 mm) column using a mobile phase composed of methanol and sodium phosphate buffer (0.05 M; pH 3.7) containing 2 ml/lit triethylamine (63:37 v/v). Detector response was monitored at excitation and emission wavelengths of 470 and 537 nm, respectively. The calibration curve was linear over the concentration range of 2 to 640 ng/ml. The lower limits of detection and quantification were 0.5 and 2 ng/ml, respectively. The validation of the analysis was carried out in terms of specificity, sensitivity, linearity, precision, accuracy and stability. The validated method was shown to be accurate, with intra-day and inter-day accuracy from 0.3 to 4.2% and precise, with intra-day and inter-day precision from 2.4 to 15.5%. The drug is detected at concentrations as low as 2 ng/ml in a 0.5 ml serum sample and the described method can be easily applied in human single-dose pharmacokinetic studies of sertraline.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

high performance liquid chromatography determination of sertraline in human

an accurate and sensitive reversed-phase high-performance liquid chromatograph-ic method for determination of sertraline in human serum is described using 4-chloro-7-nitrobenzofurazan as pre-column derivatization agent. the drug and an internal standard (azithrimycin) were extracted from serum using a mixture of diethyl ether-chloroform and subjected to the pre-column derivatization with the re...

full text

High-Performance Liquid Chromatography Determination of Methotrexate in Plasma

This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...

full text

High-Performance Liquid Chromatography Determination of Methotrexate in Plasma

This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...

full text

HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE IN HUMAN SERUM

A simple, rapid and sensitive HPLC method for the determination of theophylline (T) in human serum has been developed. An isocratic system consisting of a /-l Bondapak C18 column, mobile phase of methanol, phosphate buffer (22:78, pH=4.5), and a flow rate of 1.4 mL/min was used. The eluent was detected by UV at 275 nm at room temperature. 8-Chlorotheophylline (8-CT) was used as an internal ...

full text

Vortex-Assisted Inverted Dispersive Liquid-Liquid Microextraction of Naproxen from Human Plasma and Its Determination by High-Performance Liquid Chromatography

Extraction and determination of naproxen from human plasma were performed using Vortex-Assisted Inverted Dispersive Liquid-Liquid MicroExtraction (VA−IDLLME) and High-Performance Liquid Chromatography (HPLC). The parameters affecting extraction recovery such as type and volume of extraction and disperser solvents, pH of sample solution, stirring rate, extraction time and salt addition were ...

full text

high-performance liquid chromatography determination of methotrexate in plasma

this article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (mtx) in plasma. samples were collocted from children receiving high-dose mtx at shafa hospital (ahvaz university of medical sciences, ahvaz, iran) at various times after the end of eachinfusion. plasma was deproteinized with trichloroacetic acid and the supernatant was i...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 5  issue 3

pages  171- 178

publication date 2009-07-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com