HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE IN HUMAN SERUM

Authors

  • H TAJERZADEH From the Biopharmacy Division, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, IR.Iran, 14155/6451.
  • S SADRAY
Abstract:

A simple, rapid and sensitive HPLC method for the determination of theophylline (T) in human serum has been developed. An isocratic system consisting of a /-l Bondapak C18 column, mobile phase of methanol, phosphate buffer (22:78, pH=4.5), and a flow rate of 1.4 mL/min was used. The eluent was detected by UV at 275 nm at room temperature. 8-Chlorotheophylline (8-CT) was used as an internal standard. The serum samples deproteinated by methanol containing 8-CT and the supernatant was injected into the HPLC system. The retention times of 5.7 and 8.1 min were found for T and 8-CT, respectively. The linearity was checked in the range of 0.2- 30 µg/mL. Relative standard deviation for both inter-day and intra-day precision analysis was less than 5%. No interference was observed from endogenous serum components. Specificity was shown against some commonly co-administered drugs. Simple and fast sample preparation, small sample volume (250 µL), precision, reproducibility, specificity, sensitivity and high percentage recovery (98 %) make the method to be practically useful for T monitoring in asthmatic patients.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

high-performance liquid chromatographic determination of theophylline in human serum

a simple, rapid and sensitive hplc method for the determination of theophylline (t) in human serum has been developed. an isocratic system consisting of a /-l bondapak c18 column, mobile phase of methanol, phosphate buffer (22:78, ph=4.5), and a flow rate of 1.4 ml/min was used. the eluent was detected by uv at 275 nm at room temperature. 8-chlorotheophylline (8-ct) was used as an internal stan...

full text

High-performance liquid-chromatographic determination theophylline in plasma.

A high-performance liquid-chromatographic method is reported for monitoring theophylline in plasma. Samples are deproteinized with 2.5 volumes of acetonitrile and the supernates chromatographed on a reversed-phase column. Absorption at 275 nm is monitored. One can accurately measure 1.5 mg of theophylline per liter, in as little as 10 microliter of plasma, and only about 7 min is required per s...

full text

High-Performance Liquid Chromatographic Determination of Rivastig-mine in Human Plasma for Application in Pharmacokinetic Studies

A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using ...

full text

High Performance Liquid Chromatographic Determination of Inactive Carboxylic Acid Metabolite of Clopidogrel in Human Serum: Application to a Bioequivalence Study

        A sensitive and rapid method is described for determination of clopidogrel carboxylic acid (CCA), the inactive metabolite of the antiplatelet agent clopidogrel in human serum. The analytical procedure involves liquid-liquid extraction of the analyte and an internal standard (phenytoin) with ethyl acetate. A mobile phase consisting of 0.05 M phosphate buffer containing triethylamine (0.5...

full text

High-Performance Liquid Chromatographic Determination of Rivastig-mine in Human Plasma for Application in Pharmacokinetic Studies

A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using ...

full text

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 13  issue 3

pages  0- 0

publication date 1999-11

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023