Filter selection for 99mTc-Sestamibi myocardial perfusion SPECT imaging [Persian]
Authors
Abstract:
Myocardial perfusion SPECT imaging with Tc99m-sestamibi is the most accurate non-invasive means of detecting coronary artery disease and assessing the severity of perfusion abnormalities in the patients with coronary stenosis. Though simple and straight forward the results produced by the technique is very much affected by the details being used. One of the main problems with the test, which has created a lot of discrepancies, is the selection of proper filter and adjustment of filter parameters to individual cases. In this study we have analyzed and compared for widely used filters for myocardial Tc-99m sestamibi SPECT study i.e. Hanning, Butterworth, Metz and Wiener. The aim of the study was to find the most suitable filter for this type of study and to verify the theoretical peculiarity of the filters in practice. Patients with proven coronary artery abnormality were selected. We have investigated four conventional filters commonly used in nuclear medicine using quantitative and qualitative method. Filters were compared to each other and to the results of angiography. Our results show that the best filter in terms of contrast; smoothing and spatial resolution is the classical Metz filter with the FWHM of 4, order of 0.5. The best filter in the myocardial viability was Hanning filter with the cutoff of 0.5.
similar resources
filter selection for 99mtc-sestamibi myocardial perfusion spect imaging [persian]
myocardial perfusion spect imaging with tc99m-sestamibi is the most accurate non-invasive means of detecting coronary artery disease and assessing the severity of perfusion abnormalities in the patients with coronary stenosis. though simple and straight forward the results produced by the technique is very much affected by the details being used. one of the main problems with the test, which ha...
full textReverse perfusion pattern in myocardial spect with 99mTc-SestaMIBI
RATIONALE The aim of our study was to investigate the myocardial perfusion deficit in rest images as compared to stress images in myocardial scintigraphy (MS). OBJECTIVES The aim of this study is to investigate the reverse perfusion (RP) pattern in MS. METHODS AND RESULTS 263 patients were enrolled in the study (72 females and 191 males; mean age 65.7 ± 9.5 years old). Mean body mass index ...
full textDipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings
Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...
full textDetermination of the optimum filter for qualitative and quantitative 99mTc myocardial SPECT imaging
Background: Butterworth, Gaussian, Hamming, Hanning, and Parzen are commonly used SPECT filters during filtered back-projection (FBP) reconstruction, which greatly affect the quality and size accuracy of image. Materials and Methods: This study involved a cardiac phantom in which 1.10 cm thick cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml) 99mTc conc...
full textLarge abdominal photopenic area on 99mTc-sestamibi myocardial perfusion imaging.
(99m)Tc-sestamibi myocardial perfusion imaging is frequently performed in conjunction with exercise or pharmacologic stress testing for evaluation of coronary heart disease. Interpretation of these studies includes systematic review of unprocessed rotating projectional images for evaluation of cardiac size as well as the presence of motion or attenuation artifacts. Occasionally, incidental nonc...
full textCompensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging
Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle en...
full textMy Resources
Journal title
volume 11 issue 1
pages 41- 50
publication date 2003-11-01
By following a journal you will be notified via email when a new issue of this journal is published.
Keywords
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023