Experimental evaluation of midline dose calculation methods in In vivo dosimetry using anatomic thorax phantom

Authors

  • A. R. Naseri
  • GH. Oskoi
Abstract:

Background: In vivo dosimetry is a method for estimation of overall error in the delivered dose to the patients at the end of radiotherapy process. In this research, two methods for target dose calculation were evaluated on midline and central axis of photon beams in in vivo dosimetry of thorax fields. Materials and Methods: Entrance and exit doses for anterior and lateral fields of thorax were measured in thorax phantom using diode dosimeter. Also, the doses of some points on midline and central axis were measured in thorax phantom using ionization chamber. The dose at these points was calculated using entrance and exit doses by geometric and arithmetic mean methods. The calculated doses were compared with measured doses. Results: In all cases, arithmetic mean method showed errors from %8.8 to 19% for points on midline and central axis in comparison to measurements. The range of errors for geometric method was from %1.5 to %8 depending on distance from midline. Conclusion: The results showed that doses of points on midline and central axis can be calculated with acceptable accuracy from entrance and exit doses using geometric mean in thorax fields.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

experimental evaluation of midline dose calculation methods in in vivo dosimetry using anatomic thorax phantom

background: in vivo dosimetry is a method for estimation of overall error in the delivered dose to the patients at the end of radiotherapy process. in this research, two methods for target dose calculation were evaluated on midline and central axis of photon beams in in vivo dosimetry of thorax fields. materials and methods: entrance and exit doses for anterior and lateral fields of thorax were...

full text

Dose distribution and dosimetry parameters calculation of MED3633 palladium-103 source in water phantom using MCNP

Background: Palladium-103 (103Pd) is a brachytherapy source for cancer treatment. The Monte Carlo codes are usually applied for dose distribution and effect of shieldings. Monte Carlo calculation of dose distribution in water phantom due to a MED3633 103Pd source is presented in this work. Materials and Methods: The dose distribution around the 103Pd Model MED3633 located in the center of 30×...

full text

dose distribution and dosimetry parameters calculation of med3633 palladium-103 source in water phantom using mcnp

background: palladium-103 (103pd) is a brachytherapy source for cancer treatment. the monte carlo codes are usually applied for dose distribution and effect of shieldings. monte carlo calculation of dose distribution in water phantom due to a med3633 103pd source is presented in this work. materials and methods: the dose distribution around the 103pd model med3633 located in the center of 30×30...

full text

The Swiss IMRT dosimetry intercomparison using a thorax phantom.

PURPOSE In 2008, a national intensity modulated radiation therapy (IMRT) dosimetry intercomparison was carried out for all 23 radiation oncology institutions in Switzerland. It was the aim to check the treatment chain focused on the planning, dose calculation, and irradiation process. METHODS A thorax phantom with inhomogeneities was used, in which thermoluminescence dosimeter (TLD) and ioniz...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 5  issue None

pages  91- 95

publication date 2007-09

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023