Evaluation putty metal as internal shield for patient protection of electron therapy by Monte Carlo study
Authors
Abstract:
Introduction: In this study, a specific combination (70% W 18.61% Ni and 11.39% C) of lead free and flexible putty metal is introduced and validated as internal shielding by Mont Carlo study Materials and Methods: To evaluate putty metal as an internal shielding by Mont Carlo study Varian 2100 C/D was validated within measurement and then by given energy spectrum of Varian 2100 C/D shield thickness and backscatter factor were obtained by Mont Carlo study and compared to those of lead. Results: The results showed that this putty metal shield required comparable thickness for providing protection compared to lead. In addition, it is nontoxic and flexible in that it can be easily cut. Internal shielding with high atomic number causes dose enhancement that isn’t taken into account in treatment planning system. This study showed that this composition as internal shield causes 5-7% reduction of electron backscatter factor relative Lead. Conclusion: it can be concluded that lead can be replaced by putty metal with specific combination (70% W, 18.61% Ni and 11.39% C). It is Lead free, flexible and thickness required for protecting tissue is acceptable under clinical condition and it causes 5 -7% reduction of electron backscattering
similar resources
Monte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator
Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at...
full textTotal skin electron therapy (TSET): Monte Carlo Simulation and implementation
Introduction: Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Operating procedures for total skin electron irradiation and its dosimetry vary in different radiation therapy centers in the world. In this article, validation of TSET techniq...
full textA Monte Carlo simulation study on the effectiveness of electron filters designed for telecobalt radiation therapy treatment
Background: The aim of present study was to analyze the effectiveness of electron filters in the Telecobalt radiotherapy treatment by simulation technique. Materials and Methods: The BEAMnrc Monte Carlo code was used to simulate the electron filters of thickness of 0.5 gm/cm2 below the trimmer bar for 35 × 35 cm2 field size in Theratron Equinox-80 telecobalt unit. The electron filters were mad...
full textEvaluation of Electron Contamination in Cancer Treatment with Megavoltage Photon Beams: Monte Carlo Study
Background: Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...
full textCharacteristics of lead glass for radiation protection purposes: A Monte Carlo study
Background: Lead glass has a wide variety of applications in radiation protection. This study aims to investigate some characteristics of lead glass such as the γ-ray energy-dependent mass and linear attenuation coefficients, the half-value layer thickness, and the absorbed dose distribution for specific energy. Materials and Methods: The attenuation parameters of different lead glass types aga...
full textComparison of MCNP4C, 4B and 4A Monte Carlo codes when calculating electron therapy depth doses
ABSTRACT Background: accurate methods of radiation therapy dose calculation. There are different Monte Carlo codesfor simulation of photons, electrons and the coupled transport of electrons and photons. MCNPis a general purpose Monte Carlo code that can be used for electron, photon and coupledphoton-electron transport.Monte Carlo simulation of radiation transport is considered to be one of the ...
full textMy Resources
Journal title
volume 15 issue Special Issue-12th. Iranian Congress of Medical Physics
pages 356- 356
publication date 2018-12-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com