Evaluation of X-ray absorbed dose in thyroid during CXR imaging of the chest by Monte Carlo simulation (DOSXYZnrc)

Authors

Abstract:

Abstract:   Introduction: Chest radiography is one of the most common X-ray imaging procedures performed worldwide. During this process, in addition to the chest, other tissues, including the thyroid, are also exposed to radiation. Due to the fact that one of the most important risk factors for thyroid cancer is ionizing radiation, measuring the absorption of X- rays in the thyroid is of special importance.  Method: Energies of 100, 70 and 80 kV were used in the Monte Carlo code. 300 million particles were used in the BEAMnrc simulation and 100 million particles in the DOSXYXnrc simulation Then, using chest CT scan images obtained from patients, the chest phantom was designed by CTCREATE method.  The dose absorbed in the thyroid gland was calculated using BEAMdp from the output obtained from BEAMnrc. Results: D / Dmax was obtained in different coordinates from 0.54 to 6.91 and the calculation error was calculated from 0.32 to 18.73%. Discussion and Conclusion: Chest radiography can lead to high dose absorption in some areas of thyroid tissue. Dose absorption in thyroid is present in all energy ranges, which is typically done on chest radiographs.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Monte Carlo radiography simulation for assessment of absorbed radiation dose in femur bone marrow during X-ray radiography for constant mAs and AEC techniques

Background: The purpose of this study was to find the accurate absorbed dose in the femur bone marrow during the X-ray radiography for constant mAs and AEC techniques. Materials and Methods: The DOSXYZnrc was used to simulate radiation doses in two human femurs during diagnostic radiography. EGSnrc phantoms produced from actual CT images of human femurs were modified by adding seven micrometre ...

full text

Calculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography

Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...

full text

Absorbed dose of Fetus in SPECT-CT Imaging of Mother's Abdomen Regions using Monte Carlo method

SPECT-CT is an imaging method for diagnosing diseases and studying physiology of the body. In this type of imaging, due to the use of radiopharmaceutical for imaging (SPECT) and X-rays (CT), a relatively high dose of radiation is introduced into the patient. If the patient is pregnant, considering that the developing fetus is sensitive to any radiation in the uterus throughout the entire period...

full text

Evaluation of glandular dose in mammography in the presence of breast cyst using Monte Carlo simulation

Introduction: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. In this study, DgN is evaluated in the presence of breast cyst, which is a common disease among women and the influence of size, number and location of the cysts on the DgN is investigated. Materials and Meth...

full text

Measurement of organ dose in chest CT examination using Monte Carlo simulation

Background: Exposure conditions in CT examinations are quite different from conventional Xray. In CT examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. In order to calculate organ effective dose in chest CT, Monte Carlo simulation has been used in this study. Materials and Methods: The Impact survey data were used to determine the ...

full text

monte carlo radiography simulation for assessment of absorbed radiation dose in femur bone marrow during x-ray radiography for constant mas and aec techniques

background: the purpose of this study was to find the accurate absorbed dose in the femur bone marrow during the x-ray radiography for constant mas and aec techniques. materials and methods: the dosxyznrc was used to simulate radiation doses in two human femurs during diagnostic radiography. egsnrc phantoms produced from actual ct images of human femurs were modified by adding seven micrometre ...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 26  issue 1

pages  0- 0

publication date 2021-02

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023