Evaluation of Organ Specific peripheral dose for Gamma knife 4C based on Monte Carlo
Authors
Abstract:
Introduction: Stereotactic Gamma Knife radiosurgery has been widely used for treating brain tumors. The scattered radiation outside of treatment field (peripheral dose) can induce the secondary cancer to specific organ. This paper investigated the absorbed dose to eyes, thyroid, heart, lung, breast and colon using a Monte Carlo technique for Mird phantom. We also study the effect of depth of tumor and helmet size on the peripheral dose. Materials and Methods: In this work, gamma knife 4C was simulated as 201 surfaces disc source modelling. Based on this model, parallel beams of uniformly distributed method emitted form 201 disk sources that correspond to inner aperture for helmet. The photon beams converged at the isocenter of gamma knife. The coordinates of centers of these discs as planes to be determined using Matlab software. The 201 disc sources simulated for 4, 8, 14 and 18 mm helmet and also various tumor depth using mcnpx. Results: Large differences were observed between the organs close to target volume such as eyes and thyroid respect to organ far from target volume. The eyes received the maximum dose and the left eye dose was more than right one. Significant differences weren’t observed for organ peripheral dose with increase helmet size. The peripheral organ doses were increased with decrease of isocenter point as result of decrease depth of tumor due to decrease scattered radiation. Conclusion: Treatment planning should be considered gamma knife peripheral peripheral doses for organs near to target volume specially in surface tumor.
similar resources
Monte Carlo Evaluation of Gamma Knife Dose Profile in Real Brain Phantom
Introduction The Gamma Knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. Dose calculations required in the system are performed by GammaPlan code; in this code, brain tissue is considered uniform. In the present study, we evaluated the effect of Gamma Knife system on the obtained dose through simulating a real ...
full textEvaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife
Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...
full textDevelopment and implementation of a Monte Carlo frame work for evaluation of patient specific out- of - field organ equivalent dose
Background: The aim of this study was to develop and implement a Monte Carlo framework for evaluation of patient specific out-of-field organ equivalent dose (OED). Materials and Methods: Dose calculations were performed using a Monte Carlo-based model of Oncor linac and tomographic phantoms. Monte Carlo simulations were performed using EGSnrc user codes. Dose measurements were performed using r...
full textmonte carlo evaluation of gamma knife dose profile in real brain phantom
introduction the gamma knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. dose calculations required in the system are performed by gammaplan code; in this code, brain tissue is considered uniform. in the present study, we evaluated the effect of gamma knife system on the obtained dose through simulating a real h...
full textevaluation of the effects of inhomogeneities on dose profiles using polymer gel dosimeter and monte carlo simulation in gamma knife
introduction polymer gel dosimeters offer a practical solution to 3d dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. in this study, egsnrc calculated and pagat polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of gamma knife in homogeneous and inhomogeneous phantoms were compared with eac...
full textThorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
Background: This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation. Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...
full textMy Resources
Journal title
volume 15 issue Special Issue-12th. Iranian Congress of Medical Physics
pages 289- 289
publication date 2018-12-01
By following a journal you will be notified via email when a new issue of this journal is published.