Evaluation of Maximum Patient Skin Dose Arising from Interventional Cardiology Using Thermoluminescence Dosimeter in Mashhad, Iran

Authors

  • Arash Gholoobi Department of Cardiology, Imam Reza educational hospital, Faculty of medicine, Mashad University of Medical Sciences, Mashhad, Iran
  • Hosein Nademi Specialized Hospital Cardiovascular Jvadalaymh, Mashhad, Iran.
  • Seyedeh Farideh Baradaran Medical Physics Research Center, Medical Physics Department, Mashhad University of Medical Sciences, Mashhad, Iran.
Abstract:

Introduction The increasing practice of interventional fluoroscopy in diagnosis and treatment of cardiovascular disease has risen attention to improve radiation protection of patients and cardiologists in these relatively high dose techniques. Therefore, nowadays there is an emphasis on the measurement of radiation dose received by patients and cardiologists arising from the relevant procedures. Materials and Methods Maximum skin dose of 90 patients in two hospitals in Mashhad have been measured by a grid of 30 thermoluminescent dosimeters (TLDs). The X-ray units were Axiom Artis Siemens in both hospitals which were equipped with integrated dose area product (DAP) meters. The procedures were divided into two groups: diagnostic procedures (angiography and angiography with measurement of left or right ventricle and pulmonary artery) and therapeutic procedures (angioplasty with or without dilatation or stent and angiography with angioplasty). DAP value, fluoro time, and cumulative dose at Interventional Reference Point (CDIRP) were also registered for each procedure. Results The mean values of maximum skin dose (MSD) and DAP for diagnostic procedures were 68.51 mGy and 20.96 Gy.cm2, respectively and for therapeutic procedures 344.18 mGy and 70.94 Gy.cm2, respectively. A good correlation was found between MSD and DAP (R=0.88) but correlation between MSD and CDIRP was stronger (R=0.90).   Conclusion MSD values did not exceed the 2000 mGy dose threshold for deterministic effects. The highest MSD obtained for diagnostic procedures was 229.40 mGy and for therapeutic procedures it was 820.50 mGy. The results show that CDIRP can be a fairly good estimate of MSD.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

evaluation of maximum patient skin dose arising from interventional cardiology using thermoluminescence dosimeter in mashhad, iran

introduction the increasing practice of interventional fluoroscopy in diagnosis and treatment of cardiovascular disease has risen attention to improve radiation protection of patients and cardiologists in these relatively high dose techniques. therefore, nowadays there is an emphasis on the measurement of radiation dose received by patients and cardiologists arising from the relevant procedures...

full text

Patient dose values during interventional cardiology examinations in Yazd hospital, Iran

Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...

full text

Organ Dose Measurement in Computed Tomography Using Thermoluminescence Dosimeter in Locally Developed Phantoms

Introduction: Organ dose estimation using thermoluminescence dosimeter (TLD) is known to be a standard, although many other methods, such as simulation software, optically stimulated luminescent dosimeters, and photodiodes are still in use. This study aimed at directly measuring mean organ doses to the selected organs in the head/neck, chest, and abdominal regions from four computed tomography ...

full text

patient dose values during interventional cardiology examinations in yazd hospital, iran

background: the number of interventional cardiology (ic) procedures has increased rapidly. coronary angiography (ca) and percutaneous transluminal coronary angioplasty (ptca) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. however, it is also known that these procedures are associated with high radiation doses due to long f...

full text

Evaluation of the Entrance Skin Dose in Animals Undergoing Diagnostic Radiology Using LiF, Mg, Ti Thermoluminescence Dosimetry (TLD-100)

Introduction According to the International Commission on Radiological Protection publication numbers 60 and 21, the environmental control standards should ensure human and other species protection to a desirable degree. Since application of radiographic procedures in Veterinary Medicine has increased significantly, in this study, we aimed to evaluate the entrance skin dose to the animals (e.g....

full text

Assessment of Patient Radiation Dose in Interventional Procedures at Shahid Madani Heart Center in Khorramabad, Iran

Introduction: Coronary angiography is the most common angiographic procedure for diagnosis and treatment of the heart diseases. Herein, we aimed to evaluate the entrance surface dose (ESD), dose area product (DAP), as well as cancer risk in interventional cardiology procedures. Materials and Methods: This study was conducted during July-December 2015 at Shahid Madani Heart Center in Khorramabad...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 10  issue 2

pages  87- 94

publication date 2013-09-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023