Evaluation of Full scatter convolution algorithm based Treatment Planning System performance in the presence of inhomogeneities using three-dimensional film dosimetry

Authors

  • Ahad Zainali Medical physics department, Faculty of medicine, Urmia Medical Acience University
  • Leila Mahani Department of Medical Physics, Faculty of Medicine, Urmia University of Medical Sciences, Urmia, Iran.
Abstract:

Introduction: Inclusion of inhomogeneities such as air-filled cavities in the head and neck treatment fields may result in potential dosimetric disagreement which was caused by electronic disequilibrium. Most of treatments planning systems (TPS) are not able to predict dose distribution of inhomogeneous regions accurately. EBT2 films are used frequently in radiotherapy quality assurance testing to evaluate the performance of dose delivery systems and TPS. The development and usage of 3D film dosimetry method may be useful. Materials and Methods: 9 pieces of EBT2 films were embedded in a rectangular inhomogeneous head and neck phantom. Films were exposed with 6 MV X-ray photons with parallel-opposed fields and three approximate small field sizes were examined. A homemade computer code was developed in MATLAB for creation of 3D dose map of irradiated films and calculation of enclosed volumes which were surrounded by isodose lines of films. Calculated dose volumes should be compared with Dose Volume Histogram (DVH) which was derived from TPS. Results: our results showed significant differences between the results of the film dosimetry and TPS. Maximum difference of calculated and measured values was observed in volumes surrounded by 95% isodose curves and 3x3cm2 field size (P=0.035) and minimum difference was observed in volumes surrounded by 95% isodose curves and 5x5cm2 field size (P=0.047). Conclusion: The results of this study demonstrated overestimated results in volumetric calculation of TRGRT dose calculation algorithm in the presence of inhomogeneities and approxi small fields sizes. Also, these results confirmed that utilization of an accurate and comprehen method such as 3D film dosimetry can be useful for TPS verification.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Evaluation of Three-dimensional Treatment Planning System (TPS) performance in dose calculation of virtual wedged fields using film dosimetry

Introduction: Nowadays radiotherapy plays an important role in cancer treatment. Different radiotherapy techniques improvement emphasizes on using of the precise ، appropriate and useful algorithms. one of these techniques are wedged which is used in radiotherapy to compensate missing tissues and create a uniform dose distribution in tissues. The Siemens Artiste linear accelera...

full text

the effects of planning on accuracy and complexity of iranian efl students’ written narrative task performance

this study compared the different effects of form-focused guided planning vs. meaning-focused guided planning on iranian pre-intermediate students’ task performance. the study lasted for three weeks and concentrated on eight english structures. forty five pre-intermediate iranian students were randomly assigned to three groups of guided planning focus-on-form group (gpfg), guided planning focus...

15 صفحه اول

the effects of time planning and task complexity on accuracy of narrative task performance

هدف اصلی این تحقیق بررسی تاثیر برنامه ریزی زمانی، هم چنین افزایش میزان پیچیدگی تکالیف در نظر گرفته شده بصورت همزمان، بر دقت و صحت و پیچیدگی عملکرد نوشتاری زبان آموزان می باشد. بدین منظور، 50 نفر از دانش آموزان دختر در رده ی سنی 16 الی 18 سال به عنوان شرکت کنندگان در این زمینه ی تحقیق در نظر گرفته شدند و به دو گروه آزمایشی و کنترل بصورت اتفاقی تقسیم شدند. اعضای گروه آزمایشی هر دو تکلیف ساده و پی...

Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation

Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs). Their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. This study was designed to evaluate the dosimetric parameters of...

full text

determination of olanzapine and thiourea using electrodes modified by dna and film of copper-cobalt hexacyanoferrate & investigation of electro-oxidation of some catechol derivatives in the presence of 4-phenylsemicarbazid

چکیده هدف از این کار بررسی الکترواکسیداسیون کتکول و مشتقات آن در حضور 4-فنیل سمی کاربامازید بوده است اکسیداسیون کتکولها ترکیبات نا پایدار کینونها را تولید می کنند که این ترکیبات می تواند در واکنش مایکل بعنوان پذیرنده نوکلئوفیل عمل نمایند. در ادامه اکسایش کتکولهای (a-c1) را درحضور 4-فنیل سمی کاربامازید در محلول آب/استونیتریل (90/10)بوسیله ولتامتری چرخه ای و کولن متری در پتانسیل ثابت مورد بررسی ...

15 صفحه اول

dimensional film dosimetry with GAFCHROMIC films for quality assurance and dosimetric verification of 3D conformal radiotherapy in the presence of heterogeneities

Introduction: The presence of heterogeneities such as air-filled cavities in the head and neck treatment fields region, may result in potential dosimetric disagreement because the losses of charged particle equilibrium. Most of treatments planning systems are not able to predict dose distribution of inhomogeneities region accurately. Therefore, dose calculation algorithms need to...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  136- 136

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023