Evaluation of accuracy, precision and consensus of four laboratory glucose measurement kits with reference method

Authors

  • Jalali, MT, Department of Laboratory Sciences, School of Paramedical Sciences, Ahvaz Jundishapur University of Medical sciences, Ahvaz, Iran
  • Mohammad Taghvaie, N, Department of Laboratory Sciences, School of Paramedical Sciences, Ahvaz Jundishapur University of Medical sciences, Ahvaz, Iran
  • Saki, A, , Department of Statistics and Epidemiology, School of Environmental Health , Ahvaz Jundishapur University of Medical sciences, Ahvaz, Iran
  • Shahbazian, BB, Diabetes Research Center, Ahvaz Jundishapur University of Medical sciences, Ahvaz, Iran
Abstract:

Abstract &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Background and Objective: According to recent changes in diagnostic criteria for diabetes, the harmonization of results obtained from various methods and systems by considering their accuracy and precision is essential. This study aimed to evaluate the accuracy, precision and consensus of some routine laboratory glucose kits in comparison with Hexokinase reference method. &nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Material and Methods: The participants were 38 diabetic patients with fasting blood sugar (FBS) &ge;126 mg/dl, nine prediabetic patients with FBS of 100-125 mg/dl, 15 non-diabetic people with FBS of 60-100 mg/dl and 9 hypoglycemic patients with FBS of &le;60 mg/dl. Their FBS were measured by four routine laboratory glucose kits:&nbsp;&nbsp;&nbsp; Glucose oxidase on BT3000 analyzer with an open system and Hexokinase reference method on a close system (COBAS INTEGRA&reg;400plus analyzer, Roche kit). Accuracy and precision were determined and compared with reference method. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Results: Glucose oxidase methods showed a good agreement with the reference method, in Correlation Coefficient>0.99. based on&nbsp; regression analysis, the&nbsp; slope of 1.114 for Pars Azmoon, 1.105 for Bionik, 1.121 for Elitech and 1.087 for Human were reported (P<0.05). Error of the mean for ParsAzmoon was 12.79, for Bionik 10.86, for Elitech 12.58 and for Human were 8.46. Coefficient of Variation&nbsp;&nbsp; showed more imprecision for Bionik and Human kits. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Conclusion: given the same almost standard errors, standard devisions and regression analysis, the precision in four methods is the same but in comparison with Hexokinase, reference method has not the accuracy. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Keywords: Blood Glucose, Glucose Oxidase, Hexokinase, Methods, Consensus

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Evaluation of Accuracy, Precision and Agreement of Five Hba1c Measurement Methods with HPLC Reference Method

ABSTRACT &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Background and Objective: The current challenge of diabetes mellitus is to prevent its complications. These complications are directly associated with hyperglycemia in diabetics. The HbA1c measurement is essential for long-term glycemic control. Synchronization of HbA1c measurement is important in order to avoid discrepancies between resu...

full text

evaluation of accuracy, precision and agreement of five hba1c measurement methods with hplc reference method

abstract         background and objective: the current challenge of diabetes mellitus is to prevent its complications. these complications are directly associated with hyperglycemia in diabetics. the hba1c measurement is essential for long-term glycemic control. synchronization of hba1c measurement is important in order to avoid discrepancies between results reported by laboratories. this study...

full text

the evaluation of language related engagment and task related engagment with the purpose of investigating the effect of metatalk and task typology

abstract while task-based instruction is considered as the most effective way to learn a language in the related literature, it is oversimplified on various grounds. different variables may affect how students are engaged with not only the language but also with the task itself. the present study was conducted to investigate language and task related engagement on the basis of the task typolog...

15 صفحه اول

Developing a Method for Increasing Accuracy and Precision in Measurement System Analysis: A Fuzzy Approach

Measurement systems analysis (MSA) has been applied in different aspect of industrial assessments to evaluate various types of quantitative and qualitative measures. Qualification of a measurement system depends on two important features: accuracy and precision. Since the capability of each quality system is severely related to the capability of its measurement system, the weakness of the two...

full text

‏‎a comparative study of language learning strategies employmed by bilinguals and monolinguals with reference to attitudes and motivation‎‏

هدف از این تحقیق بررسی برخی عوامل ادراکی واحساسی یعنی استفاده از شیوه های یادگیری زبان ، انگیزه ها ونگرش نسبت به زبان انگلیسی در رابطه با زمینه زبانی زبان آموزان می باشد. هدف بررسی این نکته بود که آیا اختلافی چشمگیر میان زبان آموزان دو زبانه و تک زبانه در میزان استفاده از شیوه های یادگیری زبان ، انگیزه ها نگرش و سطح مهارت زبانی وجود دارد. همچنین سعی شد تا بهترین و موثرترین عوامل پیش بینی کننده ...

15 صفحه اول

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 9  issue 2

pages  39- 46

publication date 2015-07

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023