Estimating the Absorbed Dose of Organs in Pediatric Imaging of 99mTc-DTPA Radiopharmaceutical using MIRDOSE Software
Authors
Abstract:
Introduction: In this study, organ radiation doses were calculated for the renal agent 99mTc-DTPA in children. Bio-kinetic energy of 99mTc-DTPA was evaluated by scintigraphy and estimates for absorbed radiation dose were provided using standard medical internal radiation dosimetry (MIRD) techniques.Material and Methods: In this applied research, fourteen children patients (6 males and 8 females) were imaged using a series of planar and SPECT images after injecting with technetium-99m diethylenetriaminepentaacetic acid (99mTc-DTPA). A hybrid planar/SPECT method was used to plot time-activity curves to obtain the residence time of the source organs and also MIRDOSE software was used to calculate the absorbed dose of every organ. P-values were calculated using t-tests in order to make a comparison between the adsorbed doses of male and female groups..Results: Mean absorbed doses (µGy/MBq) for urinary bladder wall, kidneys, gonads, liver and adrenals were 213.5±47.8, 12.97±6.23, 12.0±2.5, 4.29±1.47, and 3.31±0.96, respectively. Furthermore, the mean effective dose was 17.5±3.7 µSv/MBq. There was not any significant difference in the mean absorbed dose of the two groups.Conclusion: Bladder cumulated activity was the most contribution in the effective dose of patients scanned with 99mTc-DTPA. Using a hybrid planar/SPECT method can cause an increase in accumulated activity accuracy for the region of interest. Moreover, patient-specified internal dosimetry is recommended.
similar resources
Estimation of Organ Absorbed Doses in Patients from 99mTc-diphosphonate Using the Data of MIRDose Software
The purpose of this study was to compare estimation of radiation absorbed doses to patients following bone scans with technetium-99m-labeled methylene diphosphonate (MDP) with the estimates given in MIRDose software. In this study, each patient was injected 25 mCi of (99m)Tc-MDP. Whole-body images from thirty patients were acquired by gamma camera at 10, 60, 90, 180 minutes after (99m)Tc-MDP in...
full textAssessment the Effect of Kidney Internal Structure on Gamma Absorbed Dose of Radiopharmaceutical 111In-DTPA
Large quantities of radiopharmaceuticals prescribed for treatment and diagnosis are excreted through kidney. Therefore, radiation unwanted dose is created in kidney. As a result, exact calculation of prescribed radiopharmaceuticals amount is important. Monte Carlo method is used for simulation of radiation transport in body due to random nature of radiation. In this research, for the first time...
full textAssessment the Effect of Kidney Internal Structure on Gamma Absorbed Dose of Radiopharmaceutical 111In-DTPA
Large quantities of radiopharmaceuticals prescribed for treatment and diagnosis are excreted through kidney. Therefore, radiation unwanted dose is created in kidney. As a result, exact calculation of prescribed radiopharmaceuticals amount is important. Monte Carlo method is used for simulation of radiation transport in body due to random nature of radiation. In this research, for the first time...
full textestimation of organ absorbed doses in patients from 99mtc-diphosphonate using the data of mirdose software
introduction: the purpose of this study was to compare estimation of radiation absorbed doses to patients following bone scans with technetium-99m-labeled methylene diphosphonate (mdp) with the estimates given in mirdose software. methods: in this study, each patient was injected 25 mci of 99m tc-mdp. whole-body images from thirty patients were acquired by gamma camera at 10, 60, 90, 180 minute...
full textتخمین دوز جذبی ناشی از رادیوداروی 99mTc-DMSA در بیماران کودک تحت اسکن کلیه با استفاده از نرمافزار MIRDose و با بکارگیری روش ترکیبی پلنار SPECT
Introduction: 99mTc–Dimercaptosuccinic Acid (DMSA) as evaluation of pediatric genitourinary abnormalities has an important role in pediatric nuclear medicine. The aim of this study was to estimate organs absorbed dose for children injected by 99mTc DMSA using MIRDOSE software and hybrid planar/SPECT method. Methods: After injection of 99mTc-DMSA, ten children with genitourinary abnorma...
full textAssessment the effect of kidney internal structure on gamma absorbed dose of radiopharmaceutical In-DTPA
Large quantities of radiopharmaceuticals prescribed for treatment and diagnosis are excreted through kidney. Therefore, radiation unwanted dose is created in kidney. As a result, exact calculation of prescribed radiopharmaceuticals amount is important. Monte Carlo method is used for simulation of radiation transport in body due to random nature of radiation. In this research, for the first time...
full textMy Resources
Journal title
volume 9 issue 3
pages -
publication date 2019-06-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com