Efficacy of Different Irrigation Systems Used to Remove Calcium Hydroxide from the Root Canal

Authors

  • Merve Yeniçeri Özata Research Assistant, Dicle University, Faculty of Dentistry, Department of Endodontics, Diyarbakır, Turkey
  • Meryem Kara Assistant Professor, Pamukkale University, Faculty of Dentistry, Department of Endodontics, Denizli, Turkey
  • Özkan Adıgüzel Professor, Dicle University, Faculty of Dentistry, Department of Endodontics, Diyarbakır, Turkey
  • Seda Falakaloğlu Assistant Professor, Afyonkarahisar Health Sciences University, Faculty of Dentistry, Department of Endodontics, Afyonkarahisar, Turkey
Abstract:

Introduction: The present study aimed to compare the cleaning efficacy of passive ultrasonic irrigation (PUI), self-adjusting file (SAF), EndoVac, and conventional syringe irrigation (CSI) techniques on Ca(OH)2 removal from the root canal. Methods: This study was conducted on the mesial roots of 36 human mandibular molar teeth. After 1 month, the Ca(OH)2 was removed from the experimental groups using four different irrigation techniques (SAF, PUI, EndoVac, and CSI). The inner surfaces of the canals were examined using a stereomicroscope at 30x magnification. The assessment of remaining Ca(OH)2 medicament in the grooves was performed by three calibrated dentists using a scoring system ranged 0-3. Results: None of the groups showed complete Ca(OH)2 removal from the root canals. The PUI technique removed significantly more Ca(OH)2  from all root canals, compared to EndoVac and CSI techniques  (P<0.05). In the apical third, SAF group results were significantly better than the CSI group results (P<0.05). In the middle third, the SAF technique led to significantly better results in the removal of Ca(OH)2, compared to  the techniques used in other groups (P<0.05).Conclusion: Currently, there is no irrigation system that can completely remove Ca(OH)2 from the root canal in endodontics. Regarding the removal of Ca(OH)2 from root canals, the PUI technique was significantly better than EndoVac and CSI techniques. In addition, the SAF technique showed significant efficacy in the middle third of the root canals.  

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Efficacy of the NaviTip FX irrigation needle in removing calcium hydroxide from root canal

OBJECTIVE To evaluate the effectiveness of the NaviTip FX, brush-covered irrigation needle, in removing calcium hydroxide from the root canal. STUDY DESIGN Thirty single-rooted teeth were randomly divided into three groups: A - irrigation with a hypodermic needle inserted as far as possible without binding and activation with #30 K-type file; B - Irrigation with a hypodermic needle without ac...

full text

Root canal filling with calcium hydroxide using different techniques.

Several different techniques for placing calcium hydroxide into root canals have been proposed, such as amalgam carriers, vertical pluggers, McSpadden compactors, Lentulo drills, files and special syringes. Because correct filling of the root canal is necessary for calcium hydroxide paste to act effectively, the aim of this research was to study different techniques of root canal filling with c...

full text

Removal efficiency of calcium hydroxide dressing from the root canal.

The aim of this study was to investigate whether differences in the composition of calcium hydroxide (Ca(OH)2) preparations influence the removal efficiency of irrigation solutions used in combination with filing of the canal. Three Ca(OH)2 preparations were used: Calxyl, Pulpdent paste, and chemically pure Ca(OH)2 mixed with distilled water. Fifty-one single-rooted extracted human teeth were p...

full text

Research Paper: Comparison efficacy of calcium hydroxide removal by Revo-s, Protaper Rotary file from root canal

Abstract Introduction: The aim of this study was to evaluate the efficacy of two rotary instrument systems (ProTaper and Revo-s File) in removing calcium hydroxide residues from root canal walls Materials and Methods:Thirty human  maxillary incisors were instrumented with the ProTaper System up to the F2 instrument, irrigated with 2.5% NaOCl,and filled with a calcium hydroxide intracanal dr...

full text

Comparison of the Different Techniques to Remove Fractured Endodontic Instruments from Root Canal Systems

OBJECTIVES To evaluate the success of certain methods that can be used in the removal of separated instruments from different levels in curved and straight canals. METHODS Instrument removal attempts were undertaken on 63 straight and 30 curved canals containing a pre-fractured instrument using the ultrasonics under the visualization of an operating microscope or conventional methods. In stra...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 8  issue 3

pages  121- 128

publication date 2019-09-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com