Effects of Co-Exposure to Noise and JP-4 Jet Fuel on Hearing Loss in Rats

Authors

  • Kaydany, Masomeh Department of Occupational Health and Safety, Shouahtar Faculty of Medical Sciences, Shouahtar, Iran
Abstract:

Background and Aim: Autotoxic substances such as JP-4 jet fuel can have negative effects on the auditory system by the various means such as cochlear dysfunction. The purpose of this study was to investigate the combined effects of exposure to JP-4 jet fuel and noise on hearing loss in rats, to determine the possible interference effects of these two risk factors on rat auditory system. Methods: For this purpose, 24 healthy adult male Wistar albino rats, weighing 230±25 g, were selected and randomly divided into four groups of six. One group was exposed only to noise with a bandwidth of 500-8000 Hz with a sound pressure level of 95± 2 dBA and the second group was exposed to JP-4 jet fuel with a concentration of 1100±10 mg / m3 for 8 hours per 14 consecutive days. The third group also experienced both noise and jet fuel exposure to the same conditions and the fourth group was also considered control. The assessment of hearing system in male rats was used by Distortion Product Otoacoustic Emissions testing (DPOAE). Changes in the temporal and permanent distortion emissions (TTSdp and PTSdp) in the frequency range of 0 to 8.5 kHz were compared between groups. Results: In the exposed group to noise, the level of temporary and permanent hearing loss was 6.24 and 5.35 dB, respectively. Temporary and permanent hearing loss in rats exposed to jet fuel (JP-4) was measured as 3.02 and 2.85 dB, respectively.  In the group co-exposed to noise and jet fuel, permanent and temporary hearing loss were reported being 13.43 and 12.02 dB, respectively. Conclusion: The results of the present study showed that independent exposure to noise and jet fuel (JP-4) can lead to temporary and permanent hearing loss; moreover, there was the stronger effects on auditory system in co-exposure condition. The exposure to Jet fuel may increase risk for noise adverse effect on hearing loss. However, more comprehensive research is required to reveal more aspects of the interference effect of co-exposure noise with different characteristics such as level and frequency and jet fuel with different types and concentrations.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Subchronic JP-8 jet fuel exposure enhances vulnerability to noise-induced hearing loss in rats.

Both laboratory and epidemiological studies published over the past two decades have identified the risk of excess hearing loss when specific chemical contaminants are present along with noise. The objective of this study was to evaluate the potency of JP-8 jet fuel to enhance noise-induced hearing loss (NIHL) using inhalation exposure to fuel and simultaneous exposure to either continuous or i...

full text

Urinary biomarkers of exposure to jet fuel (JP-8).

Benzene, naphthalene, and 1- and 2-naphthol were measured in urine samples obtained from 322 U.S. Air Force personnel categorized a priori as likely to have low, moderate, or high exposure to jet fuel [jet propulsion fuel-8 (JP-8)]. In postexposure samples, levels of these analytes in the high-exposure group were 3- to 29-fold greater than in the low-exposure group and 2- to 12-fold greater tha...

full text

Effect of Ascorbic Acid on Noise Induced Hearing Loss in Rats

Introduction: After presbycusis, noise-induced hearing loss is the second most common cause of acquired hearing loss. Numerous studies have shown that high-intensity noise exposure increases free radical species; therefore, use of antioxidants to detoxify the free radicals can prevent cellular damage in the cochlea. We studied the potential hearing protective effect of different doses of ascorb...

full text

Hearing loss after noise exposure.

The higher field strength magnetic resonance imaging (MRI) such as 3 Tesla (T) and above generates noise that has potential detrimental effects on the hearing. Temporary threshold shifts following MRI examination have been reported for MRI with lower field strength. Such effect, however, have not been reported so far for a 3T MRI. We report a case that exemplifies the possible detrimental effec...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 22  issue 4

pages  341- 352

publication date 2020-07

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023