Effectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code

Authors

  • AA Mowlavi Professor of Nuclear Physics, Physics Department, School of Science, Hakim Sabzevari University, Sabzevar, Iran
  • AR Nazempour MSc student of Radiation Medicine, Radiation Medicine Department, Shahid Beheshti University, Tehran, Iran
  • HR Baghani PhD student of Radiation Medicine, Radiation Medicine Department, Shahid Beheshti University, Tehran, Iran
  • SM Hosseini Daghigh PhD student of Radiation Medicine, Radiation Medicine Department, Shahid Beheshti University, Tehran, Iran
  • SMR Aghamiri Professor of Radiation Medicine, Radiation Medicine Department, Shahid Beheshti University, Tehran, Iran
Abstract:

Background and Objective: The most common intravascular brachytherapy sources include 32P, 188Re, 106Rh and 90Sr/90Y. In this research, skin absorbed dose for different covering materials in dealing with these sources were evaluated and the best covering material for skin protection and reduction of absorbed dose by radiation staff was recognized and recommended.Method: Four materials including polyethylene, cotton and two different kinds of plastic were proposed as skin covers and skin absorbed dose at different depths for each kind of the materials was calculated separately using the VARSKIN3 code.Results: The results showed that for all sources, skin absorbed dose was minimized when using polyethylene. Considering this material as skin cover, maximum and minimum doses at skin surface were related to 90Sr/90Y and 106Rh, respectively.Conclusion: polyethylene was found the most effective cover in reducing skin dose and protecting the skin. Furthermore, proper agreement between the results of VARSKIN3 and other experimental measurements indicated that VRASKIN3 is a powerful tool for skin dose calculations when working with beta emitter sources. Therefore, it can be utilized in dealing with the issue of radiation protection.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

effectiveness evaluation of skin covers against intravascular brachytherapy sources using varskin3 code

background and objective: the most common intravascular brachytherapy sources include 32p, 188re, 106rh and 90sr/90y. in this research, skin absorbed dose for different covering materials in dealing with these sources were evaluated and the best covering material for skin protection and reduction of absorbed dose by radiation staff was recognized and recommended. method: four materials includin...

full text

Skin Dosimetry of Some Beta Sources using the VARSKIN2 Code

Introduction: Skin dose and depth dose distribution of some beta sources that can contaminate skin or protective clothing covering the skin have been calculated using VARSKIN2. Materials and Methods: In this research, absorbed dose to skin and depth dose from the skin surface have been calculated for 90Sr/90Y, 147Pm, 32P beta emitter radioisotopes by using input parameters: activity of source, ...

full text

skin dosimetry of some beta sources using the varskin2 code

introduction: skin dose and depth dose distribution of some beta sources that can contaminate skin or protective clothing covering the skin have been calculated using varskin2. materials and methods: in this research, absorbed dose to skin and depth dose from the skin surface have been calculated for 90sr/90y, 147pm, 32p beta emitter radioisotopes by using input parameters: activity of source, ...

full text

Accuracy Evaluation of Oncentraâ„¢ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code

Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...

full text

Calibration and characterization of beta-particle sources for intravascular brachytherapy.

The calibration of a catheter-based system to be used for therapeutic radiation treatment to prevent restenosis following interventional coronary procedures is described. The primary dosimetry was performed ionometrically using an extrapolation chamber equipped with a 1-mm diameter collecting electrode to measure absorbed dose in tissue equivalent plastic at a depth of 2 mm. These results are c...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 3  issue 4

pages  -

publication date 2013-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023