Effective Dose Evaluation of Critical Organes in Digital Radiography Exames

author

Abstract:

Background and Aim: Due to the increasing number of radiographic tests, TLD dosimeters can be used to measure the effective dose of critical organs in various radiographic tests. In this research, the progression of analogue to digital radiology devices, which facilitates and accelerates the performance of radiographs, especially emergency patients, was investigated, and then the effective dose of critical organs in digital radiographic devices was calculated using a thermoluminescence dosimeter. Materials and Methods: In this cross-sectional study 29 thermoluminescence GR-200 dosimeters(LiF: Mg, Cu, P) were used first, the TLDs were calibrated by the Atomic Energy Organization of Tehran Protection Center, then using TLDs, equivalent doses were used in radiographic tests and finally, the effective dose of critical organs was calculated. Results: Data were analyzed using Anova in SPSS software. The mean effective doses of critical organs were 0/034±0/0015 mSv for eyes(in skull radiography), 0/0063±0/0004 for thyroid(in cervical radiography), 0/0067±0/0009 for breast(in lung radiography) and 0/2010±0/0652 for ovarian(in abdominal radiography). We found significant differences between effective doses of thyroid and ovaries in common position(Postero Anterior)(p˂0.05). We found non-significant differences between effective doses of the eyes and breast in common position(AntroPosterior)(p˃0.05). Conclusion: According to the results of this study, the effective dose of the patient in radiographic exames depends on the thickness of the target organ and the patient's position, which has a significant effect on the dose of radiation absorbed by the patient.  

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...

full text

patient effective dose evaluation for chest x-ray examination in three digital radiography centers

background: the radiation doses resulting from diagnostic x-ray examinations are routinely measured in terms of entrance surface dose (esd) and effective dose (ed). in this study, for the purpose of radiation protection, the radiation doses received from digital chest x-ray examination were evaluated in terms of esd and ed. material and methods: the ed was calculated by using the mcnp monte car...

full text

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

1Medical Physics and Biomedical Engineering Department, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran 2Nuclear Sciences Research School, Radiation Applications Research School, Tehran, Iran 3National Radiation Protection Department, Iranian Nuclear Regulatory Authority, Teheran Iran 4Nuclear Sciences Research School, Nuclear Sciences and Technology Research Institute, ...

full text

Evaluation of Image Magnification in Digital Panoramic Radiography

Introdouction: The aim of the present study was to investigate image magnification in digital panoramic radiography and assess the effect of anatomical sites on the magnification in both males and females. Materials and methods: In this retrospective study, digital panoramic radiographs of 48 patients with 202 implants were investigated. Implant diameter and length were measured on pan...

full text

Effective dose efficiency: an application-specific metric of quality and dose for digital radiography.

The detective quantum efficiency (DQE) and the effective DQE (eDQE) are relevant metrics of image quality for digital radiography detectors and systems, respectively. The current study further extends the eDQE methodology to technique optimization using a new metric of the effective dose efficiency (eDE), reflecting both the image quality as well as the effective dose (ED) attributes of the ima...

full text

Patient dose management in digital radiography

PURPOSE To present the experience in patient dose management and the development of an online audit tool for digital radiography. MATERIALS AND METHODS Several tools have been developed to extract the information contained in the DICOM header of digital images, collect radiographic parameters, calculate patient entrance doses and other related parameters, and audit image quality. RESULTS Th...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 14  issue 3

pages  264- 274

publication date 2020-07

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023