Effect of saliva and blood contamination on shear bond strength of cured dentin adhesives

Authors

  • Shidoush, Elham
Abstract:

Effect of saliva and blood contamination on shear bond strength of cured dentin adhesives Dr. E. Yassini* - Dr. E. Shidoush** *- Professor of Operative Dentistry Dept. - Faculty of Dentistry - Tehran University of Medical Sciences. ** - Dentist. Background and Aim: Achieving good moisture control is a common problem encountered in restorative dentistry, especially after applying and curing dentin bonding agents over dentin tissue. The aim of this study was evaluation of the effect of saliva and blood contamination on shear bond strength of cured dentin adhesives. Materials and Methods: Thirty-five extracted sound human molars and premolars were collected and after debridement, stored in 0.5% chloramine solution for one week and preserved in distilled water, afterwards. The buccal and lingual surfaces were ground flat to expose the dentin. These surfaces were etched with 37% phosphoric acid for 15 seconds, rinsed for 20 seconds and dried with a cotton pellet. A single–bottle dentin-bonding agent was applied on the etched surfaces and cured for 20 seconds. This procedure was repeated in order to achieve excellent bonding. The specimens were divided into five groups of 7 each: Group 1 (Control) was not contaminated in Group 2, bonding surfaces were contaminated with blood and saliva without any other treatment Group 3 was contaminated and then rinsed and dried completely Group 4 was contaminated, then rinsed and dried and re-etched for 10 seconds Group 5 was contaminated, rinsed and completely dried, re-etched for 10 seconds, rinsed, dried, re-bonded and cured for 20 seconds. A composite cylinder built in a plastic mold (2 mm high × 10 mm wide) was placed on the treated surfaces and cured for 40 seconds. After thermocycling, the shear bond strengths of all specimens were measured using an Instron testing machine. The data were subjected to one-way ANOVA, with 95% coefficient of confidence. Results: A significant difference was observed between the mean shear bond strength of the contaminated and uncontaminated groups (P=< 0.001). Conclusion: Contamination of cured dentin bonding agents with blood and saliva, significantly reduced the shear bond strength of composite to dentin. Key words: One bottle adhesive - Saliva contamination - Blood contamination - Shear bond strength

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Effect of salivary contamination on shear bond strength of three different dentin adhesive systems

Effect of salivary contamination on shear bond strength of three different dentin adhesive systems Dr. H. Kermanshah* - Dr. H. Haj miragha** - Dr. SH. Gatoeizadeh*** *- Assistant Professor of Operative Dentistry Dept. - Faculty of Dentistry – Tehran University / Medical Sciences. **- Assistant Professor of Fixed Prosthodontics Dept. & Dental Research Center - Faculty of Dentistry – Tehran Unive...

full text

Comparison of shear bond strength of stainless steel brackets bonded with three light- cured adhesives

Introduction: The bonding process of the brackets to enamel has been a critical issue in orthodontic research. The purpose of this study was to evaluate the shear bond strength of 3 light-cured adhesives (transbond XT, Z250, light bond). Materials &Methods: In this study sixty extracted human premolars were collected and randomly divided into 3 test groups. All teeth were etched by 37% phosp...

full text

Effect of blood contamination during adhesive restorative procedures on dentin-resin cement shear bond strength

Effect of blood contamination during adhesive restorative procedures on dentin-resin cement shear bond strength Carlos José Soares1 Carolina Assaf Branco2 Priscilla Barbosa Ferreira Soares1 Rodrigo Borges Fonseca1 Hugo Lemes Carlo1 Alfredo Júlio Fernandes Neto2 1Department of Operative Dentistry and Dental Materials, Dental School Federal University of Uberlândia. 2Department of Occlusion and F...

full text

Effects of blood contamination on microtensile bond strength to dentin of three self-etch adhesives.

This study evaluated the effects of blood contamination and decontamination methods during different steps of bonding procedures on the microtensile bond strength of two-step self-etch adhesives to dentin. Sixty extracted human molars were ground flat to expose occlusal dentin. The 60 molars were randomly assigned to three groups, each treated with a different two-step self-etch adhesive: Clear...

full text

Effect of water and saliva contamination on the shear bond strength of a new light-cured cyanoacrylate adhesive.

AIM The purpose of the study was to assess the effect of water and saliva contamination on the shear bond strength and site of bond failure of two different orthodontic adhesives (Transbond XT and cyanoacrylate Smartbond LC). MATERIALS AND METHODS 120 bovine permanent mandibular incisors were randomly divided into 6 groups, and each group consisted of 20 specimens. Each adhesive was tested un...

full text

The effect of cavity disinfectants on the micro-shear bond strength of dentin adhesives

OBJECTIVES This study was carried out to examine the effect of application of four different disinfecting agents on the micro-shear bond strength (μ-SBS) of an etch-and-rinse and self-etch adhesive systems. MATERIALS AND METHODS One hundred flat dentin surfaces of human molars were produced by wet grinding the buccal surfaces. Specimens were randomly assigned to five groups according to the d...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 18  issue 3

pages  0- 0

publication date 2006-06

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

No Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023