Abstract:

Introduction: Currently, the potential application of gold nanoparticles (AuNPs) to increase the efficiency of radiation therapy have been investigated. However, the loss of an appropriate method to estimate the dose distribution in nanoparticle laden tissue limits the applicability of nanoparticles in radiotherapy clinics. Polymer gel dosimetry provides an accurate and precise system that enables to measure the dose distribution in full three dimension. In this study, the radiation dose enhancement effect of AuNPs was assessed through gel dosimetry analysis. Materials and Methods: To achieve the mentioned goal, AuNPs were impegrated in MAGIC_f polymer gel dosimeter and irradiated by 6Mv X-ray beam. Irradiated gel was then evaluated by two modalities of Magnetic Resonance Imaging (MRI) and Optical Computed Tomography (OCT). Results: MRI and OCT scanning of the MAGIC_f geles containing 0.1 mM AuNPs demonstrated dose enhancements of 7.8% and 6.8%, respectively. Conclusion: Polymer gel dosimetry has the potential to provide a new platform for investigation and optimization of the applicability of nanoparticles in radiation therapy

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Dose enhancement effect of gold nanoparticles on MAGICA polymer gel in mega voltage radiation therapy

Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. Among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. Material and Methods: In this study...

full text

Effect of Gold Nanoparticle on Percentage Depth Dose Enhancement On Megavoltage Energy in MAGICA Polymer Gel Dosimeter

Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date.Objective: The aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material.Methods: In this work t...

full text

Evaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter

Background: Gold nanoparticles (GNPs) are among the most promising radiosensitive materials in radiotherapy. Studying the effective sensitizing factors such as nanoparticle size, concentration, surface features, radiation energy and cell type can help to optimize the effect and possible clinical application of GNPs in radiation therapy. In this study, the radiation sensitive polymer gel was use...

full text

dose enhancement effect of gold nanoparticles on magica polymer gel in mega voltage radiation therapy

background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. material and methods: in this study...

full text

effect of gold nanoparticle on percentage depth dose enhancement on megavoltage energy in magica polymer gel dosimeter

background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. objective: the aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material. methods: in this work...

full text

Gel dosimetry: The effect of gold nanoparticles on the dose enhancement in the external radiation therapy

Background: Normoxic type MAGICA gel dosimeters are established for dose quantification in three dimensions for radiotherapy. Objective(s): The ability of MAGICA polymer gel was assessed by experimental measurements method for studying the effect of gold nanoparticles (GNPs) in dose enhancement under the external 18MV radiotherapy practices. <...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  114- 114

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023