Dosimetry Comparison of Water Phantom and Complete Eye Definition for 125I and 103Pd Brachytherapy Plaques

Authors

  • Somayeh Asadi Graduated M.Sc. Student of Nuclear Physics, Physics Dept., KN Toosi University of Technology, Tehran, Iran.
  • Zohreh Dehghannia Rostami Graduated M.Sc. Student of Nuclear Physics, Physics Dept., KN Toosi University of Technology, Tehran, Iran.
Abstract:

Introduction: In this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125I and 103Pd. Material and methods: The simulation of the two phantoms were performed in the MCNP-4C code and by using the geometry of a three-dimensional eye, different parts of the eye including the lens, cornea, retina, choroid, sclera, anterior chamber, optic nerve and tumor were defined in the eye phantom. Also, for two ophthalmic brachytherapy sources, 20 mm COMS plaques containing 24 125I or 103Pd sources were simulated. The depth dose and doses in different parts of the eye were calculated by using the *F8 tally in the MCNP code. Results: The results showed that the doses in different parts of the eye in the two phantoms were different and depended on the ophthalmic plaques. The dose increased in the tumor and decreased in some parts of the eye such as the lens. Discussion and Conclusion: Complete definition of human eye in simulation of ophthalmic brachytherapy leads to better results. As the effects of eye definition are different in the tumor and healthy tissues, the results for the eye phantom provide more accurate information for calculation of treatment time and the type of ophthalmic brachytherapy used.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

dosimetry comparison of water phantom and complete eye definition for 125i and 103pd brachytherapy plaques

introduction: in this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125i and 103pd. material and methods: the simulation of the two phantoms were performed in the mcnp-4c code and by using the geometry of a three-dimensional eye, differen...

full text

103Pd versus 125I ophthalmic plaque brachytherapy: preoperative comparative radiation dosimetry for 319 uveal melanomas

OBJECTIVE This study was conducted to compare the relative, clinical intraocular dose distribution for palladium-103 (103Pd) versus iodine-125 (125I) ophthalmic plaque radiation therapy. METHODS Preoperative comparative radiation dosimetry was performed to evaluate 319 consecutive uveal melanomas treated between 2006 and 2012. RESULTS There were 68 (21.3 %) anterior (iris and/or ciliary bod...

full text

Ocular brachytherapy dosimetry for 103Pd and 125I in the presence of gold nanoparticles: a Monte Carlo study

The aim of the present Monte Carlo study is to evaluate the variation of energy deposition in healthy tissues in the human eye which is irradiated by brachytherapy sources in comparison with the resultant dose increase in the gold nanoparticle (GNP)-loaded choroidal melanoma. The effects of these nanoparticles on normal tissues are compared between 103Pd and 125I as two ophthalmic brachytherapy...

full text

Modification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd seeds

Background: A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC), is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet.Objective: The present study aims to modify source strength for different configurations of 125I and 103...

full text

The Effect of Scattering from Leg Region on Organ Doses in Prostate Brachytherapy for 103Pd, 125I and 131Cs Seeds

Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125I, 103Pd, and 131Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the ...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 8  issue 2

pages  19- 26

publication date 2011-06-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023