Dosimetric comparison of conventional and field-in-field techniques in early stage breast cancer radiotherapy

Authors

  • Mahdi Momennezhad Department of Medical Physics, Faculty of Medicine, Mashhad University of medical sciences, Mashhad, Iran Medical physics Research Center, Faculty of Medicine, Mashhad University of medical sciences, Mashhad, Iran Department of Radiotherapy and Oncology, Imam Reza Hospital, Mashhad, Iran
  • Seyed Mohammad Hosseini Department of Medical Physics, Faculty of Medicine, Mashhad University of medical sciences, Mashhad, Iran Medical physics Research Center, Faculty of Medicine, Mashhad University of medical sciences, Mashhad, Iran
Abstract:

Introduction: Breast conserving surgery followed by adjuvant radiotherapy (RT) of the whole breast is accepted as the treatment of choice in early stage breast cancer. Due to breast irregularities, it is difficult to access homogenous dose distribution with conventional techniques. Currently, it is possible to use varied breast irradiation techniques, such as field- in-field (FIF), to apply a more homogenous distribution of doses within target volumes, and organs at risk (OAR) sparing which lead to achieve better treatment outcome. This study aimed to compare conventional and FIF techniques dosimetrically Materials and Methods: Twenty patients with early-stage breast cancer underwent computed tomography (CT) with a 16 Slice CT simulator; datasets were transferred to the treatment planning system (TPS) via a digital imaging communications in medicine (DICOM). Two different treatment plans were created for each patient by the same medical physicist: a wedge base (conventional) plan and a FIF plan. Then, dosimetric and monitor unit (MU) results were compared. Results: Dosimetric indices in the planning target volume (PTV) were more satisfying with the FIF technique than with three dimensional-conformal RT (3D-CRT). FIF reduced the maximum doses of PTV and MU. In addition, the FIF technique reduced doses to the heart (in left-side irradiation cases) and ipsilateral lung by 7% and 8%, respectively. FIF also significantly reduced V40 (volume receiving 40 Gy) of heart in left side breast irradiation. V20 of lung (volume receiving 20 Gy), and also doses to the contralateral lung did not differ significantly. Conclusion: FIF can produce more homogenous doses within the PTV, and reduce doses to the OAR. Moreover, by using the FIF technique in breast irradiation, MUs required for therapy are significantly decreased compared with that required by 3D-CRT.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

full text

dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

background: we aimed to compare field-in-field technique (fif) with conformal tangential field radiotherapy (crt) in terms of dosimetric benefits for early stage breast cancer radiotherapy. materials and methods: twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. for each patient, two different treatment plans were created for...

full text

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

*Corresponding author: Dr. Guler Yavas, Selcuk University, Faculty of Medicine Department of Radiation Oncology, Konya, Turkey. Fax: +90 332 241 60 65 E-mail: [email protected] Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods...

full text

Comparison of forward intensity modulated radiation therapy and two field tangential wedged beam techniques in radiotherapy of breast cancer: dosimetric and radiobiologic study

Introduction: This study aims to compare the dose delivery parameters and radiobiologic model prediction of Tumor Control Probability (TCP) of the FIMRT technique compared with rectangular two tangential wedged fields (2FW) in the treatment of breast cancer. Furthermore, reduction of the heart and lung dose in the FIMRT was studied via dosimetric parameters and radiobiologic mo...

full text

Dosimetric outcomes of the breast field-in-field (FIF) radiotherapy technique in patients with mastectomy and lumpectomy surgeries

Background: Field-in-field (FIF) technique for treatment of breast cancer has become a widely performed method over the recent years. However, there was no study in the application of FIF technique in patients with breast cancer undergoing mastectomy and lumpectomy. This study is an attempt to compare dosimetric outcomes after applying the FIF technique in these patients. Materials and Methods:...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  19- 19

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.