Dose-volume Analysis of Heart and Lung during 3D planning of Tangential Breast Cancer Irradiation

Authors

  • Ali Jomehzadeh Assistant Professor, Department of Medical Physics, Kerman University of Medical Sciences, Kerman, Iran
  • Mohammad Hasan Larizadeh Associate Professor, Department of Radiation Oncology& Physiology Research Center, Institute of Basic and Clinical Physiology Sciences, Kerman University of Medical Sciences, Kerman, Iran
  • Zahra Jomehzadeh Instructor, Department of Medical Physics, Kerman University of Medical Sciences, Kerman, Iran
Abstract:

Background: Breast cancer is becoming more frequently diagnosed at early stages with improved long term outcomes. Radiation-related heart disease and lung cancer can occur following radiotherapy for breast cancer. The aim of this study was to evaluate some dosimetric parameters of heart and lung during whole breast radiotherapy. Methods:Twenty five consecutive patients with breast cancer who underwent radiotherapy were included in this study. Plans that employed the 3D conventional radiotherapy technique (Tangential Technique) were generated for each patient. Dose-volume histograms (DVHs) were calculated and dosimetric parameters such as, mean dose/volume receiving a dose 30 Gy (V30), mean dose/ volume receiving a dose 20 Gy (V20) for heart and lung were assessed, respectively. Results:The average of mean dose of heart on left and right side irradiation was 9.68±5.10 Gy and 1.23±1.51 Gy, respectively. The average of mean dose of ipsilateral lung on left and right side irradiation was 14.49±4.07 Gy and 11.69±3.37 Gy, respectively. The percentage of heart volume that received at least 30 Gy was 16.32±9.56% for the left-sided treatment. The percentage of lung volume that received at least 20 Gy was 23.47±11.05% and 24.12±7.77% respectively on the left and right-sided breast irradiation. Conclusion: Tangential beam conventional radiotherapy of the chest wall of postmastectomy breast cancer patients provides the potential to significantly keep the DVH parameters of heart and lung as low as the QUANTEC constrains.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Dose-volume Analysis of Heart and Lung during 3D Planning of Tangential Breast Cancer Irradiation

Introduction: Breast cancer is becoming more frequently diagnosed at early stages with improved long-term outcomes. Radiation-related heart disease and lung cancer can occur following radiotherapy for breast cancer. The aim of this study was to evaluate some dosimetric parameters of heart and lung during whole breast radiotherapy. Materials and Methods: Twenty...

full text

The Comparison 2D and 3D Treatment Planning in Breast Cancer Radiotherapy with Emphasis on Dose Homogeneity and Lung Dose

Introduction: Breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is usually used for this purpose. This technique is performed using 2D or 3D treatment planning systems. The aim of this study was to compare 2D treatment planning with 3D treatment planning in tangential irradiation in breast conse...

full text

Comparison of “heart and lung volume absorbed dose” between electron and photon boost radiotherapy after breast conserving surgery

Background: Breast conserving surgery (BCS) followed by radiotherapy (RT) has been widely accepted as the standard treatment in early stages of invasive breast cancer. The standard technique of RT includes whole breast irradiation (WBI). Additional tumor bed boost irradiation has also an important role in the local tumor control. But there are various controversial delivery methods. The aim of ...

full text

Verification of the accuracy of 3D calculations of breast dose during tangential irradiation: measurements in a breast phantom

This report specifically describes the use of a unique anthropomorphic breast phantom to validate the accuracy of three-dimensional dose calculations performed by a commercial treatment-planning system for intact-breast tangential irradiation. The accuracy of monitor-unit calculations has been corroborated using ionization chamber measurements made in this phantom. Measured doses have been comp...

full text

the comparison 2d and 3d treatment planning in breast cancer radiotherapy with emphasis on dose homogeneity and lung dose

introduction: breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. a tangential parallel-opposed pair is usually used for this purpose. this technique is performed using 2d or 3d treatment planning systems. the aim of this study was to compare 2d treatment planning with 3d treatment planning in tangential irradiation in breast conse...

full text

Calculation of Neutron Dose Ratio of Heart, Lung and Liver due to breast cancer Proton Therapy using MCNPX code

Introduction: The proton beam produced in particle accelerators has an appropriate therapeutic potential. In this research, proton therapy of breast cancer is simulated using the MCNPX code in a MIRD phantom, also the contribution of scattered neutron dose during the proton therapy were calculated for the Heart, Lung and Liver.   Materials and Methods: For si...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 25  issue 3

pages  255- 264

publication date 2018-05-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023