Dose Reduction Methods in Chest Computed Tomography

Authors

  • jalal ordoni M.S of radiobiology., Department of radiology, Faculty of Para medicine, zahedan University of Medical Sciences, zahedan. Email
  • Vida sargazi M.S of medical physic., Department of radiology, Faculty of Para medicine, zahedan University of Medical Sciences, zahedan. Email: [email protected]
  • zeynab yazdi sotode M.S of mri., Department of radiology, Faculty of Para medicine, zahedan University of Medical Sciences, zahedan. Email:[email protected]
Abstract:

Introduction: Computed tomography is one of the most powerful tools for investigating thorax disease, because it shows progression of lung disease much clearer than chest radiography. Technical advances in CT scanners have led to some abilities for CT scanners such as coverage of larger volume, lower noise and ability for acquiring image in one respiratory phase. However, this will be accompanied by more radiation exposure to patient and research shows that CT gives higher exposure dose to patient in comparison with conventional radiography.1   Materials and Methods: In each computed tomography (CT), patient dose is dependent on the scan parameters. Scan parameters are included kV, mA, scan field of view (SFOV), rotation time, focal spot size, slice width and pitch. Also, shielding of sensitive organs such as breast which is not interest organ during chest CT scanning is one of the dose reduction methods. Furthermore, Type of scanner, methods and protocols of scanning, for example in multi-slice scanners there is some more cases like collimation, which effect on patient dose, and therefore all of these options should be adjusted, accurately. It is considerable that scan parameters such as reconstructed matrix and reconstruction algorithms have considered in this paper; however, these parameters do not impact directly on patient dose but they have some affects through changing the characteristics of the image indirectly. In this study twenty methods for radiation dose reduction in thorax CT were explained. Conclusion: According to the principle of ALARA, the aim of applying optimization techniques is to reduce the amount of receiving dose while maintaining image quality.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

[Fluoroscopy dose reduction of computed tomography guided chest interventional radiology using real-time iterative reconstruction].

The purpose of this study was to evaluate the radiation dose reduction to patients and radiologists in computed tomography (CT) guided examinations for the thoracic region using CT fluoroscopy. Image quality evaluation of the real-time filtered back-projection (RT-FBP) images and the real-time adaptive iterative dose reduction (RT-AIDR) images was carried out on noise and artifacts that were co...

full text

Automated aortic calcium scoring on low-dose chest computed tomography.

PURPOSE Thoracic computed tomography (CT) scans provide information about cardiovascular risk status. These scans are non-ECG synchronized, thus precise quantification of coronary calcifications is difficult. Aortic calcium scoring is less sensitive to cardiac motion, so it is an alternative to coronary calcium scoring as an indicator of cardiovascular risk. The authors developed and evaluated ...

full text

Reduction of uterus dose in clinical thoracic computed tomography.

PURPOSE The aim of this study was to investigate the potential dose reduction in the uterus as a result of lead apron protection during thoracic CT scans. Moreover, the distribution of the radiation dose in the uterus was determined in order to obtain information about the ratio of internally and externally scattered radiation. MATERIALS AND METHODS The uterus doses during thoracic CT were de...

full text

Evaluation of Metal Artifact Reduction software in Computed Tomography

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...

full text

Radiation dose reduction in computed tomography perfusion using spatial-temporal Bayesian methods

In current computed tomography (CT) examinations, the associated X-ray radiation dose is of significant concern to patients and operators, especially CT perfusion (CTP) imaging that has higher radiation dose due to its cine scanning technique. A simple and cost-effective means to perform the examinations is to lower the milliampere-seconds (mAs) parameter as low as reasonably achievable in data...

full text

Dose Reduction to the Thyroid Gland in Pediatric Chest Radiography

Background  It is remain a main concern that pediatric chest radiographies contribute to the significant radiation exposure to the thyroid gland as a more susceptible organ to radiation induced cancer. The aim of this study was to evaluate the entrance surface dose (ESD) of pediatric chest radiography compared to the diagnostic reference levels (DRL) and evaluation the efficacy of the lead (Pb)...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  77- 77

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023