Dose Evaluation for Common Digital Radiographic Examinations in Selected Hospitals in Pahang Malaysia
Authors
Abstract:
Introduction: In digital radiography, radiographers tend to increase exposure factors to acquire an acceptable image quality thereby increasing radiation dose to patients. Regarding this, the present study aimed to re-evaluate the exposure parameters and to ascertain the entrance surface dose (ESD) and effective dose (ED) of posterior-anterior (PA) chest, abdomen, and anterior-posterior (AP) lumbosacral spine radiography. Materials and Methods: This study was conducted on 180 physically able patients with age of 20-60 years and weight of 60-80 kg referred to Hospital Sultan Haji Ahmad Shah (HOSHAS) and Hospital Tengku Ampuan Afzan (HTAA).Image acquisition was performed using digital radiography. The ESD and ED were determined using CALDose_X 5.0 software. Results: The ESD and ED for PA chest were 0.098 mGy and 0.012 mSv in HOSHAS, while in HTAA were 0.161 mGy and 0.021 mSv respectively. Regarding the abdomen, the ESD and ED were 2.57 mGy and 0.311 mSv in HOSHAS and 2.16 mGy and 0.262 mSv in HTAA respectively. For AP lumbosacral spine, the ESD and ED for HOSHAS were 2.65 mGy and 0.222 mSv, while in HTAA were 2.357 mGy and 0.201 mSv respectively. Conclusion: The findings revealed the use of high kVp, automatic exposure control, correct focus image receptor distance, tight collimation and additional filter resulted in a lower ESD. The ESD and ED obtained in this study were comparable with those reported by other studies and lower than the values recommended by the United Nations Scientific Committee on the Effects of Atomic Radiation in 2008.
similar resources
A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography
Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...
full textOptimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations
IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization inv...
full textMelioidosis in Pahang, Malaysia.
We conducted a retrospective review of 135 patients with melioidosis in Pahang from January 2000 to June 2003. Patients were mostly male (78.5%) and Malay (83%) with a median age of 51 years. Seventy four percent of patients were diabetic. Common presentations were pneumonia (40.7%), septicaemic without obvious source of infection (19.3%) and multiple organ involvement (15.6%). Only 32.7% were ...
full textPaediatric Dose AssessmentToward Establishment of National Diagnostic Reference Levels for Digital Radiography Examinations in Iran
Introduction: Paediatric patients deserve special attention because of the higher radiation risks compared with adults. The main purpose of this study is to determine patient dose and diagnostic reference level for Paediatric through Entrance Surface Dose (ESD) calculations in common X-ray examination and to establish Paediatric national DRLs in digital radiography in Iran. <...
full textPediatric melioidosis in Pahang, Malaysia.
Melioidosis is much less common in children than in adults. This study investigated the incidence, demographic characteristics, presenting symptoms and outcome of pediatric melioidosis in Pahang, Malaysia. This retrospective study included patients < or =18 years old with positive body fluid cultures for Burkholderia pseudomallei from January 2000 to June 2003. Data on culture results were obta...
full textEntrance surface dose measurements for routine X-ray examinations in Chaharmahal and Bakhtiari hospitals
Background: There is not any report on the radiation doses received by patients in diagnostic radiology sections in hospitals under control of Chaharmahal and Bakhtiari Medical Sciences University, in the south west of Iran. Objectives: The aim of this study is measurement of entrance surface doses (ESD) for the most routine types of X-ray procedures in radiology centers as part of ongoing d...
full textMy Resources
Journal title
volume 14 issue 3
pages 155- 161
publication date 2017-09-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023