dimensional film dosimetry with GAFCHROMIC films for quality assurance and dosimetric verification of 3D conformal radiotherapy in the presence of heterogeneities

Authors

  • Ahad Zeinali Department of Medical Physics, Faculty of Medicine, Urmia University of Medical Sciences, Urmia, Iran.
  • Kamal Mostafanezhad Radiotherapy Department, Omid hospital, , Urmia, Iran
  • Leila Mahani Department of Medical Physics, Faculty of Medicine, Urmia University of Medical Sciences, Urmia, Iran.
  • Milad Zeinali Kermani Department of Medical Physics, Faculty of Medicine, Urmia University of Medical Sciences, Urmia, Iran.
Abstract:

Introduction: The presence of heterogeneities such as air-filled cavities in the head and neck treatment fields region, may result in potential dosimetric disagreement because the losses of charged particle equilibrium. Most of treatments planning systems are not able to predict dose distribution of inhomogeneities region accurately. Therefore, dose calculation algorithms need to model electron transport accurately. GAFchromic films are used in routine radiotherapy quality assurance procedure to perform comprehensive dosimetry. The development and using 3D dosimetry may be useful. Materials and Methods: several pieces of GAFchromic films were embedded in an in-house manufactured rectangular inhomogeneous head and neck phantom. A 6 MV photon beam from a Siemens Primus linear accelerator, equipped with the standard multileaf collimator (MLC) was assessed. Different approximately small field sizes were examined. A homemade computer code was developed for reconstruction of 3D dose map of irradiated Gafchromic. The measured data by film were compared to the similar data calculated by TPS in dose- volume histogram (DVHs). Results: The data calculated by TPS compared with the measure data based on 3- dimensional film dosimetry. Our results showed significant differences between the results of the film dosimetry and TPS. Maximum difference of calculated and measured values observed for volume enclosed in 95% isodose curves and 3x3cm2 field size (P=0.035). For this field size the dose calculated by TPS, after the air cavity differed from the film measurements on average by 42%. The disagreement between measured and calculated data was increased with decreasing of field size. Conclusion: our results demonstrated this TPS based on full scatter convolution algorithm doesn’t have acceptable performance in heterogeneous regions and approximately small fields and overestimated dose at some areas like air cavity or interface of air/tissue. Also our results confirmed that utilization of some accurate and comprehensive method such as 3D film dosimetry can be useful beside other methods of QA methods.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Precise film dosimetry for stereotactic radiosurgery and stereotactic body radiotherapy quality assurance using Gafchromic™ EBT3 films

PURPOSE The purpose of this study is to evaluate the dosimetric uncertainty associated with Gafchromic™ (EBT3) films and establish a practical and efficient film dosimetry protocol for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT). METHOD AND MATERIALS EBT3 films were irradiated at each of seven different dose levels between 1 and 15 Gy with open fields and standar...

full text

the analysis of the role of the speech acts theory in translating and dubbing hollywood films

از محوری ترین اثراتی که یک فیلم سینمایی ایجاد می کند دیالوگ هایی است که هنرپیش گان فیلم میگویند. به زعم یک فیلم ساز, یک شیوه متأثر نمودن مخاطب از اثر منظوره نیروی گفتارهای گوینده, مثل نیروی عاطفی, ترس آور, غم انگیز, هیجان انگیز و غیره, است. این مطالعه به بررسی این مسأله مبادرت کرده است که آیا نیروی فراگفتاری هنرپیش گان به مثابه ی اعمال گفتاری در پنج فیلم هالیوودی در نسخه های دوبله شده باز تولید...

15 صفحه اول

The use of radiochromic EBT2 film for the quality assurance and dosimetric verification of 3D conformal radiotherapy using Microtek ScanMaker 9800XL flatbed scanner

Radiochromic and radiographic films are widely used for radiation dosimetry due to the advantage of high spatial resolution and two-dimensional dose measurement. Different types of scanners, including various models of flatbed scanners, have been used as part of the dosimetry readout procedure. This paper focuses on the characterization of the EBT2 film response in combination with a Microtek S...

full text

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

full text

Dosimetric Study of an Indigenous and Heterogeneous Pelvic Phantom for Radiotherapy Quality Assurance

Introduction: In vitro dosimetric verification prior to patient treatment plays a key role in accurate and precision radiotherapy treatment delivery. Since the human body is a heterogeneous medium, the aim of this study was to design a heterogeneous pelvic phantom for radiotherapy quality assurance. Material and Methods: A pelvic phantom was ...

full text

determination of olanzapine and thiourea using electrodes modified by dna and film of copper-cobalt hexacyanoferrate & investigation of electro-oxidation of some catechol derivatives in the presence of 4-phenylsemicarbazid

چکیده هدف از این کار بررسی الکترواکسیداسیون کتکول و مشتقات آن در حضور 4-فنیل سمی کاربامازید بوده است اکسیداسیون کتکولها ترکیبات نا پایدار کینونها را تولید می کنند که این ترکیبات می تواند در واکنش مایکل بعنوان پذیرنده نوکلئوفیل عمل نمایند. در ادامه اکسایش کتکولهای (a-c1) را درحضور 4-فنیل سمی کاربامازید در محلول آب/استونیتریل (90/10)بوسیله ولتامتری چرخه ای و کولن متری در پتانسیل ثابت مورد بررسی ...

15 صفحه اول

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  378- 378

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023