Diagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey

Authors

  • Mina Nouri Department of Radiology Technology, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
  • Mohsen Asadinezhad Department of Radiology Technology, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
Abstract:

Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cities in 12 provinces of Iran. A calibrated pencil-shaped ionization chamber, standard head and body CT dosimetry phantoms and a radiation monitor were used to determine and calculate Computed Tomography Dose Index (CTDI) and Dose Length Product (DLP). The DLP-based estimates of effective dose were derived using effective dose conversion coefficients. Results: The nCTDIw values for head phantoms fell within the range of 22.05-168.38 and 43.77-426.69 µGy/mAs for 5 and 10mm slice thicknesses, respectively. These values for body phantom were 4.65-146.39 and 9.43-308.92 µGy/mAs for 5 and 10mm slice thicknesses, respectively. The third quartile of CTDIvol and DLP values for head CT examinations were 49.85 mGy and 1161.00 mGy-cm, respectively. The body CT examinations had the values of 8.89 mGy and 370.97 mGy-cm, respectively. The findings of this study revealed that the above-mentioned values can be considered as national diagnostic reference levels for head and body CT examinations in Iran. Conclusion: The results of the current study suggested that there is a need to re-assess DRLs for CT examinations at regular time intervals by the appropriate regulatory authority which can improve the continuous performance of CT scanners in Iran.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Diagnostic Reference Level of Computed Tomography Examinations and Need for Dose Optimization in Ondo State, Nigeria

Introduction: The present study was conducted to obtain State diagnostic reference levels (DRLs) of five routine computed tomography (CT) examinations from two CT centers in Ondo State and to identify factors responsible for dose variation and escalation in these CT centers. Material and Methods: Acquisition parameters and CT dose indices wer...

full text

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

full text

Estimation of diagnostic reference levels for children computed tomography: A study in Tehran, Iran

Background: The Diagnostic reference levels (DRLs) play a critical role in the optimization of radiation dose especially, in some conditions like pediatrics. They are useful indicators by which the radiologists can be aware of delivered excess radiation doses to the patients, and take corrective actions if necessary. In order to meet some requirements for establishing the national computed tomo...

full text

Paediatric Dose AssessmentToward Establishment of National Diagnostic Reference Levels for Digital Radiography Examinations in Iran

Introduction: Paediatric patients deserve special attention because of the higher radiation risks compared with adults. The main purpose of this study is to determine patient dose and diagnostic reference level for Paediatric through Entrance Surface Dose (ESD) calculations in common X-ray examination and to establish Paediatric national DRLs in digital radiography in Iran. <...

full text

Local Diagnostic Reference Levels for Common Computed Tomography Procedures at a Tertiary Hospital in South Africa

Introduction: An operational computed tomography (CT) scanner is a major source of human exposure to ionizing radiation. Exposure increases the risk of cancer and aplastic anaemia. All radiation exposures should be justified and optimized to meet the clinical objective. In order to avoid the administration of excessive radiation dose to patients, diagnostic reference l...

full text

A local study on diagnostic reference levels estimation for children computed tomography

Introduction: The Diagnostic reference levels (DRLs) play a critical role in the optimization of radiation dose especially, in some conditions like pediatrics. They are useful indicators by which the radiologists can be aware of delivered excess radiation doses to the patients, and take corrective actions if necessary. In order to meet some requirements for establishing the nat...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 16  issue 1

pages  19- 26

publication date 2019-01-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023