Diagnostic reference levels at intraoral and dental panoramic examinations

Authors

  • G. Hodolli Institute of Occupational Medicine, Radiation Protection Service, 15000 Kastriot, Kosovo
  • G. Nafezi Institute of Occupational Medicine, Radiation Protection Service, 15000 Kastriot, Kosovo
  • M. Bahtijari University of Prishtina “HasanPrishtina”, Department of Physics, 10000 Pristine, Kosovo
  • N. Syla University of Prishtina “HasanPrishtina”, Department of Physics, 10000 Pristine, Kosovo
  • S. Kadiri Institute of Occupational Medicine, Radiation Protection Service, 15000 Kastriot, Kosovo
Abstract:

Background: The aim of this study was to measure and determine diagnostic reference levels (DRLs) of programs used at intraoral and dent panoramic examinations in Kosovo. Materials and Methods: To determine DRL, were performed measurements for dose area product (DAP) at intraoral and dental panoramic radiology systems. This study has covered over 47% of X-ray units, which are in use for intraoral and panoramic imaging examinations on the country.  Results: From results, we conclude that, the mean of DAP (mGy cm2) for single intraoral examination is 26.8, 29.6 and 39.7 for incisor, premolar and molar, respectively. Therefore the mean of DAP (mGy cm2) value for panoramic dental radiology is 62.7, 74.1 and 90.3 for child, adult and large adult, respectively. For each modality mention above are proposed specific DRLs. Conclusion: Recommended DRLs value for intraoral radiography for incisor, premolar and molar programs are: 28.5, 36.5 and 50.3 mGy cm2, respectively. Also, DRLs for dental panoramic radiography for child, adult and large adult programs are: 73.0, 81.0 and 93.0 mGy cm2, respectively. A better quality assurance (QA) and quality control (QC) should be enforcement. For strengthening of QA and QC engagement of radiographers and Medical Physicist is mandatory.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Diagnostic reference levels in intraoral dental radiography in Korea

PURPOSE The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. MATERIALS AND METHODS One hundred two intraoral dental radiographic machines from all regions of South Korea were selected...

full text

Diagnostic Reference Level Arising from Dental Panoramic Radiography

Introduction The present work describes a study in which, based on patient dose measurements, thermoluminescent dosimeters were used to obtain the diagnostic reference level arising from panoramic radiography. Materials and Methods Ten panoramic units and a sample of 15 patients per X-ray unit were studied. Two thermoluminescent dosimeter chips were placed on the skin surface of selected organs...

full text

Local Diagnostic Reference Levels for Some Common Diagnostic X-Ray Examinations In Sabzevar County of Iran

Introduction: Diagnostic reference level (DRL) is a useful tool for the promotion of optimization. The national DRLs (NDRLs) are useful, brief, and robust guidelines for optimizing radiation protection in a country. The aim of this study was to extract the local DRLs (LDRLs) for some common radiologic examination in Sabzevar county. Materials and Methods: There are eight radiology departments ...

full text

The need for national diagnostic reference levels: Entrance surface dose measurement in intraoral radiography

Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection (ICRP) recommendations, the selection of a diagnostic reference level (DRL) should be specific to a country or region. Critica l organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low ...

full text

diagnostic reference level arising from dental panoramic radiography

introduction the present work describes a study in which, based on patient dose measurements, thermoluminescent dosimeters were used to obtain the diagnostic reference level arising from panoramic radiography. materials and methods ten panoramic units and a sample of 15 patients per x-ray unit were studied. two thermoluminescent dosimeter chips were placed on the skin surface of selected organs...

full text

Diagnostic reference levels for X-ray examinations in Slovenia

Background. Medical applications of ionizing radiation are by far the largest man-made source of radiation exposure for the population in most developed countries. A good practice in diagnostic radiology should produce an image containing all necessary information needed for accurate diagnosis and should result in the minimum dose to the patient. After introduction of diagnostic reference level...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 17  issue 1

pages  147- 150

publication date 2019-01

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023