Development of A New Electrochemical Sensor based on Zr-MOF/MIP for Sensitive Diclofenac Determination

Authors

  • Alireza Mohadesi Department of Chemistry, Payame Noor University, P.O. Box 19395-4697 Tehran, Iran
  • Maryam Malekzadeh Department of Chemistry, Payame Noor University, P.O. Box 19395-4697 Tehran, Iran
  • Mehdi Ranjbar Pharmaceutics Research Center, Institute of Neuropharmacology, Kerman University of Medical Sciences, Kerman, Iran
  • Mohammad Ali Karimi
Abstract:

In this study, a new molecularly imprinted polymer with nanoporous material of zirconium metal-organic frameworks (Zr-MOF/MIP) for diclofenac (DFC) measurement is presented. The Zr-MOF/MIP was prepared by electropolymerization method, the Zr-MOFs were used to increase electrode surface and the DFC and para- aminobenzoic acid (pABA) were used as template and functional monomer, respectively. Zr--MOFs was characterized by using X-ray powder diffraction (XRD), scanning electron microscope (SEM) and Fourier transform infrared spectroscopy (FTIR). The electrochemical performance was investigated using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Sensor response was evaluated by comparing the electrochemical response of Zr-MOF/MIP, with that of non- Imprinted polymer (NIP), in a 2.0 mM potassium ferrocyanide solution containing 0.2 mM sodium sulfate as probe solution. Measurements were carried out in the potential range of -0.6 to +1.0 V with scan rate of 50 mV/s. The calibration curve of diclofenac was linear in the concentration range of 6.5 μM to 1.5×10+3 μM. Detection limit was obtained 0.1 μM and relative standard deviation of several (n=7) replicate measurements for 1.0 mM DFC concentration has obtained 1.8%. Furthermore, favorable sensitivity, selectivity, good reproducibility and long-term stability, was obtained in the experiment and the proposed electrode was applied for the determination of DFC in pharmaceutical commercial sample with satisfactory results.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Fabrication of an Electrochemical Sensor Based on a New Nano-ion Imprinted Polymer for Highly Selective and Sensitive Determination of Molybdate

In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...

full text

fabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

A New Electrochemical Sensor for Determination of Zolpidem by Carbon Paste Electrode Modified with SnS@SnO2NP

Zolpidem is a drug that is easily attached to the GABA receptors in the brain. This property makes it very effective for tranquilizing as well as hypnagogia. According to the advantages of electrochemical analysis like high selectivity, high sensitivity, low concentration of analyte, cost-effective, portable and easy-to-use setup, they gained high amount of attention among scientists for determ...

full text

A Sensitive Electrochemical Sensor for Determination of Imipramine in Urine Sample Using Carbon Ionic Liquid Electrode Modified With Montomorillonite Nanoclay

We used an effective electrochemical sensor for the determination of imipramine at pH 7.2 using a carbon nanocomposite electrode. The electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. The high sensitivity of 1.714 μA (μM)-1, two linear calibration ranges of 0.1–2 μM and 2-40 μM, and detection limit of 19 nM were achieved. The relati...

full text

Design and Simulation of a New Highly Sensitive Gas Sensor Based on Negative Refraction Photonic Crystal

In this paper, design and simulation of a new highly sensitive gas sensor based on a hybrid photonic crystal (PC) structure, containing negative and positive refractive index sections, is presented. It has been shown that using a PC with negative refraction in the first section, the transmitted power is concentrated on the entrance of the sensing channel, and the transmission of the proposed se...

full text

Fabrication of a Selective and Sensitive Electrochemical Sensor Modified with Magnetic Molecularly Imprinted Polymer for Amoxicillin

A modified electrochemical sensor for the determination of amoxicillin (AMX) was reported in this paper. The magnetic molecularly imprinted polymer (MMIP) were suspended in AMX solution and then collected on the surface of a magnetic carbon paste electrode (CPE) via a permanent magnet, situated within the carbon paste electrode and then the voltammetry signals were recorded. It was confirmed th...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 12  issue 3

pages  402- 414

publication date 2020-03-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023