Determining the optimal size of a ground source heat pump within an air-conditioning system with economic and emission considerations

Authors

  • Hossein Yousefi Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
  • Mohammad Hasan Ghodusinejad Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
  • Younes Noorollahi Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
Abstract:

One of the most challenging issues in modern-day building energy management involves equipping the buildings with more energy efficient facilities. In this paper, a hybrid system for cooling/heating for a residential building is developed and optimized. The system consists of a ground source heat pump (GSHP) as well as an electric chiller (EC) and boiler. The model is implemented in MATLAB and optimized using NSGA-II. Two economic and environmental objective functions are considered: Net Present Cost (NPC) and Carbon Emission (CE); which are minimized simultaneously. The results indicated that when the building load is completely met by GSHP, much less carbon is emitted to the environment, while when the majority of the load is provided by EC and boiler, NPC is lower and CE is much higher.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Assessment and Deployment of Ground Source Heat Pump for Air Pollution Reduction in Tehran, Iran

The use of renewable energies, especially in metropolises has led to a reduction in environmental pollution and greater access to clean, renewable and sustainable energy. This paper evaluates the effectiveness of a national plan adopted by the Tehran city council for reducing air pollutions. This plan is designed to increase the share of renewable energies in residential buildings. This study a...

full text

Performance Assessment of a Variable Capacity Air Source Heat Pump and a Horizontal Loop Coupled Ground Source Heat Pump System

This study evaluates the performance of air source heat pump (ASHP) and ground source heat pump (GSHP) systems individually and as part of their associated heating and cooling distribution systems in two semi-attached houses. Over the monitoring period, the performance of both heat pumps exceeded manufacturer and EnerGuide ratings, with Coefficients of Performance (COPs) above 5 in the cooling ...

full text

Optimal Design for a Hybrid Ground-Source Heat Pump

Although the advantages of ground-source heat pumps over their conventional alternatives make these systems a very attractive choice for air conditioning, not only for residential buildings but increasingly also for institutional and commercial buildings, a significant barrier to wider application of this technology is a high first cost. When used in cooling-dominated buildings, ground-source h...

full text

Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology

The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...

full text

an investigation about the relationship between insurance lines and economic growth; the case study of iran

مطالعات قبلی بازار بیمه را به صورت کلی در نظر می گرفتند اما در این مطالعه صنعت بیمه به عنوان متغیر مستفل به بیمه های زندگی و غیر زندگی شکسته شده و هم چنین بیمه های زندگی به رشته های مختلف بیمه ای که در بازار بیمه ایران سهم قابل توجهی دارند تقسیم میشود. با استفاده از روشهای اقتصاد سنجی داده های برای دوره های 48-89 از مراکز ملی داده جمع آوری شد سپس با تخمین مدل خود بازگشتی برداری همراه با تعدادی ...

15 صفحه اول

Extremum Seeking Control of Hybrid Ground Source Heat Pump System

The Hybrid Ground Source Heat Pump (GSHP) system features the combination of ground heat exchanger (GHE) and cooling tower for rejecting the cooling load, which enables the use of the renewable resource of geothermal energy while reducing the cost of installation for applications of high cooling demand. However, model based control for efficient operation of the GSHP system can be intricate due...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 5  issue 3

pages  219- 226

publication date 2017-09-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023