Determination of Riboflavin by Nanocomposite Modified Carbon Paste Electrode in Biological Fluids Using Fast Fourier Transform Square Wave Voltammetry
Authors
Abstract:
Herein, fast Fourier transformation square-wave voltammetry (FFT-SWV) as a novel electrochemical determination technique was used to investigate the electrochemical behavior and determination of Riboflavin at the surface of a nanocomposite modified carbon paste electrode. The carbon paste electrode was modified by nanocomposite containing Samarium oxide (Sm2O3)/reduced graphene oxide (RGO) (2:1) to improve detection sensitivity of Riboflavin under optimal experimental conditions. Furthermore, the signal-to-noise ratio was significantly increased by application of discrete fast Fourier transformation analysis, background subtraction and two-dimensional integration of the electrode response over the selected potential range and the time window. Obtained cyclic voltammograms demonstrated a diffusion-controlled reversible electron transfer reaction for Riboflavin in phosphate buffer solution (pH=7.2). The peak potential values were pH-dependent, involving the same numbers of protons and electrons. To obtain the maximum sensitivity, some effective parameters such as scan rate (10 mV/s), accumulation time (0.2 s) and potential (+400 mV), frequency (1420 Hz) and amplitude (20 mV) were optimized. As a result, determination of Riboflavin using FFT-SWV showed a linear range of response from 10 to 400 nM (R2=0.9993), with limit of detection of 0.86 nM. An acceptable recovery percent was also obtained for Riboflavin in human plasma samples as criteria of measurement applicability of the proposed modified electrode.
similar resources
Determination of Quercetin in a Pharmaceutical Sample by Square-Wave Voltammetry Using a Poly(vinylpyrrolidone)-Modified Carbon-Paste Electrode
Um eletrodo de pasta de carbono modificado com o polímero poli(vinilpirrolidona) foi avaliado para o estudo eletroquímico e a determinação eletroanalítica da quercetina. Sobre este eletrodo, voltamogramas cíclicos da quercetina apresentaram três picos de oxidação localizados em +0,32, +0,78 e +1,04 V. A eletro-oxidação no primeiro pico conduz à formação da orto-quinona correspondente, a qual po...
full textElectrochemical Determination of Amitriptyline using a Nanocomposite Carbon Paste Electrode in Human Body Fluids
A carbon nanocomposite electrode has been designed by incorporation of montmorillonite nanoclayinto the carbon ionic liquid electrode for the electrochemical determination of amitriptiline . The surface ofthe proposed electrode was characterized by scanning electron microscopy. The presence of ionic liquid asa binder is believed to be responsible for the electrocatalytic activity of the propose...
full textDetermination of Nicotinic Acid by Square Wave Voltammetry on a Carbon Paste Electrode: the Crucial Effect of Electrode Composition and Analytical Conditions
The foregone studies have shown that nicotinic acid cannot produce noticeable reductive signal at carbon-based electrodes without appropriate modification of the electrode. This is an obvious reason that mercury is known as the main electrode material for electro-reduction of nicotinic acid. In this study, it has been shown that it is possible to create a remarkable reduction signal for NA at a...
full textelectrochemical determination of amitriptyline using a nanocomposite carbon paste electrode in human body fluids
a carbon nanocomposite electrode has been designed by incorporation of montmorillonite nanoclayinto the carbon ionic liquid electrode for the electrochemical determination of amitriptiline . the surface ofthe proposed electrode was characterized by scanning electron microscopy. the presence of ionic liquid asa binder is believed to be responsible for the electrocatalytic activity of the propose...
full textSquare-Wave Adsorptive Cathodic Stripping Voltammeteric Determination of Manganese (II) Using a Carbon Paste Electrode Modified with Montmorillonite Clay
Manganese is an essential micronutrient for all organisms; however at high concentrations it has a toxic effect. Manganese toxicity is a serious constraint to crop cultivation since it is taken-up by plants and can easily be passed into the food chain again causing symptoms of Parkinson’s disease. A fully validated square-wave adsorptive cathodic stripping voltammetry method has been developed ...
full textA sensitive method for electrochemical determination of molybdenum (VI) in plant foodstuff samples using Ni0.5Zn0.5Fe2O4 nanocomposite modified carbon paste electrode
In the present study, a new chemically modified carbon paste electrode (CPE) is constructed for rapid, accurate, simple, highly sensitive, and selective determination of Mo (VI) using differential pulse voltammetry. The electrode was prepared using magnetic nickel zinc ferrite nanocomposite (Ni0.5Zn0.5Fe2O4), as the modifier in CPE (Ni0.5Zn0.5Fe2O4/CPE). Mo (VI) was determined after preconcentr...
full textMy Resources
Journal title
volume 33 issue 9
pages 1696- 1702
publication date 2020-09-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023