Air-Conditioning (AC) systems are responsible for a considerable portion of the energy consumption in buildings located in high cooling load requiring regions of Iran. In addition, the heat flow through the buildingschr('39') external walls plays a major role in cooling load estimations for the countrychr('39')s hot regions. Therefore, application of insulation materials in external walls has gained more interest in recent years. In the present research, a systematic approach for optimizing the insulation material thickness was developed and applied for regions in Iran requiring high cooling load namely, Bandar abbas and Bushehr through utilizing life cycle cost analysis. Moreover, a correlation between optimum thickness and thermal conductivity of insulation materials was recommended for the buildings located in the mentioned hot regions of the country. The study showed that the relationship between the optimum insulation thickness and thermal conductivity has a non-linear trend and obeys a polynomial function.
similar resources
a time-series analysis of the demand for life insurance in iran
با توجه به تجزیه و تحلیل داده ها ما دریافتیم که سطح درامد و تعداد نمایندگیها باتقاضای بیمه عمر رابطه مستقیم دارند و نرخ بهره و بار تکفل با تقاضای بیمه عمر رابطه عکس دارند
Parametric Investigation of Optimum Thermal Insulation Thickness for External Walls
Numerous studies have estimated the optimum thickness of thermal insulation materials used in building walls for different climate conditions. The economic parameters (inflation rate, discount rate, lifetime and energy costs), the heating/cooling loads of the building, the wall structure and the properties of the insulation material all affect the optimum insulation thickness. This study focuse...
full textImpacts of Building Insulation on Energy Consumption in Different Climates of Iran: A Cost Analysis
One of the most important energy-saving of building is suitable choice of insulation with regard to the climatic conditions of each region. In this study, the effects of building insulations approved by the Research Center of Way, Housing and Urban Development with regard to the cost of insulation on energy consumption in the region of Yazd, Tehran and Tabriz was evaluated by software Energy Pl...
full textOptimum Insulation Thickness for Building Exterior Walls in 32 Regions of China to Save Energy and Reduce CO2 Emissions
China accounts for approximately 30% of the CO2 emissions—one of the largest proportions from a single nation. Therefore, reducing the CO2 emissions in China will play a decisive role in global CO2 emissions reduction. This paper is a proposal of optimum insulation thickness (OIT) for the exterior walls of buildings in 32 regions of China to save energy and reduce CO2 emissions. The determinati...
full textcost benefits of rehabilitation after acute coronary syndrome in iran; using an epidemiological model
چکیده ندارد.
Impact of the insulation materials’ features on the determination of optimum insulation thickness
The optimum thickness of the building envelope insulation materials depends on a large number of parameters. But the optimum thickness is calculated considering only economic arguments. In this paper, life-cycle assessment of the materials used in the building, and specifically the insulation ones, are included in the process to calculate the optimum insulation thickness from both environmental...