Determination of Magnesium (II) by a Coated Graphite Electrode Based on Risperidone as an Ionophore

author

  • Neda Hajizadeh M. A. In Analytical chemistry, Technical assistant of Jestar Sanat Company, No.28, Gilan St, Tehran, Iran.
Abstract:

In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed from them. The designed electrode could also be used in partially non aqueous mediums up to the presence of 20% of organic solvents without any tangible alteration in Nernstian slope and linearity domain. The response time and life span of the proposed electrode were 20s and 2 months respectively. The function of the electrode was inspected in solutions with different pH value and also as an indicator electrode in potentiometric titration with EDTA.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Determination of Mn2+ in Pharmaceutical Supplements by a Novel Coated Graphite Electrode Based on Zolpidem as a Neutral Ion Carrier

Manganese plays a key role in the health of human beings therefore, its determination is very important in medical fields. In this regards, a novel coated graphite electrode was constructed for determination of manganese (II) by using zolpidem as an ionophore, for the first time. The best performance was obtained of the membrane composition of PVC (32%), Potassium tetrakis (4-chlorophenyl) bora...

full text

Determination of Cobalt(II) by a New PVC Membrane Coated Graphite Electrode Based on 6-chloro-11- azabenzo[a]phenothiazin-5-one as a neutral ion carrier

Cobalt has great biological effects on human beings and also other living organisms, hence its determination is very important. In this regard, a novel coated graphite electrode was designed for determination of Co2+ ions by exploiting 6-chloro-11- azabenzo[a]phenothiazin-5-one as a neutral ion carrier, for the first time. The foremost function was witnessed from the membrane composition of PVC...

full text

Al(III) Coated Wire Selective Electrode Based on 5-Bromo(salicylidene-2-aminothiophenol) Schiff Base as a New Ionophore

A new Al(III) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (PVC) matrix is coated on platinum wire to determine trace amounts of Al(III) ion in various samples. The sensor exhibits a good response for Al(III) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 M  with Nernstian slope of 19...

full text

A new lead(II)-selective PVC-coated graphite rod electrode based on a Schiff base complex.

A new lead(II)-selective electrode has been developed based on bis(acetylacetone)-p-phenylenediamine-lead(II) [LPb(NO3)2]H2O complex ionophore as a sensing material, dioctylphthalate (DOP) as a solvent mediator and PVC as a matrix. This electrode exhibits a linear Nernstian response over the concentration range of 1 x 10(-5)-1 x 10(-1) mol l(-1) of Pb(II) cation, with a cationic calibration slo...

full text

Extraction of Co(II) by Isocyanate Treated Graphite Oxides (iGOs) Adsorbed on Surfactant Coated C18 Before Determination by FAAS

A simple, highly sensitive, accurate and selective method for determination of trace amounts of Co(II) in water samples is presented. Isocyanate treated graphite oxides (iGOs) solid phase extraction adsorbent was synthesized by covalently isocyanate onto the surfaces of graphite oxides. The stability of a chemically (iGOs) especially in concentrated hydrochloric acid which was then used as a re...

full text

Extraction of Co(II) by Isocyanate Treated Graphite Oxides (iGOs) Adsorbed on Surfactant Coated C18 Before Determination by FAAS

A simple, highly sensitive, accurate and selective method for determination of trace amounts of Co(II) in water samples is presented. Isocyanate treated graphite oxides (iGOs) solid phase extraction adsorbent was synthesized by covalently isocyanate onto the surfaces of graphite oxides. The stability of a chemically (iGOs) especially in concentrated hydrochloric acid which was then used as a re...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 6  issue 3

pages  198- 214

publication date 2019-09-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023