Determination of Diagnostic Reference Level in routine Computed radiography examination in north of Iran

Authors

  • Ali shabestani Monfared Professor of Medical Physics, Department of Medical Physics Radiobiology and Radiation Protection, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran
  • Fatemeh Niksirat MSc of Medical Physics Radiobiology and Radiation Protection Department, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran
  • Kourosh Ebrahimnejad Gorji PHD of Medical Physics, Department of Medical Physics Radiobiology and Radiation Protection, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran
  • Mohammad Reza Deevband PHD of Medical Physics, Department of Medical Physics and Engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Roya Bordbar Msc Student of Medical Physics Radiobiology and Radiation Protection Department, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran
Abstract:

Introduction: Digital radiography has a major role in nowadays healthcare system so radiation protection (justification and optimization) is important in this field. Many related organizations to protection suggested to establish national and regional diagnostic reference level for medical procedures. Reference levels are typically set at the 75th percentile of the dose distribution from a survey conducted across a broad user base using a special dose measurement protocol and phantom. This study aimed to establish diagnostic reference level for computed radiography examination in north of Iran. Materials and Methods: The data were collected from 7 public hospitals for 12 computed radiographies routine examination including: skull (AP-LAT), cervical (AP-LAT), chest (PA –LAT), thoracic (AP- LAT), lumbar(AP-LAT), abdomen(AP) and pelvis (AP). For each projection, 10 patients at least 18 years olds were investigated. The study was performed by filling out the questioner which was contained the following parameters: Center name, machine manufacturer, Type of Examination, Tube Voltage (kVp), Current Time Product (mAs) and Film Focus Distance (FFD). The quantity of entrance skin dose is evaluated by measuring ESD. The third quartile of ESD related to each projection was considered as DRL of that examination. Results: Based on the data of this study, we expected that diagnostic reference level of computed radiography examination in north of Iran is in accordance with standard values that were suggested by regulatory organizations such as American College of Radiology (ACR)and European Commission (EC). Conclusion: The comparison of the results of this survey with surveys performed in other countries will indicate the protection level of patients in computed radiography examination in north of Iran.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

full text

analyzing patterns of classroom interaction in efl classrooms in iran

با به کار گیری روش گفتما ن شنا سی در تحقیق حا ضر گفتا ر میا ن آموزگا را ن و زبا ن آموزا ن در کلا سهای زبا ن انگلیسی در ایرا ن مورد بررسی قرار گرفت. ا هداف تحقیق عبا رت بودند از: الف) شنا سا ئی سا ختارهای ارتبا ط گفتا ری میا ن معلمین و زبا ن آموزا ن ب) بررسی تا ثیر نقش جنسیت دبیرا ن و زبا ن آموزان بر سا ختا رهای ارتبا ط گفتا ری میا ن آنها پ) مشخص کردن اینکه آ یا آموزگاران غا لب بر این ارتبا ط گف...

the impact of e-readiness on ec success in public sector in iran the impact of e-readiness on ec success in public sector in iran

acknowledge the importance of e-commerce to their countries and to survival of their businesses and in creating and encouraging an atmosphere for the wide adoption and success of e-commerce in the long term. the investment for implementing e-commerce in the public sector is one of the areas which is focused in government‘s action plan for cross-disciplinary it development and e-readiness in go...

(revitalizing silk road corridor in the region (north east of iran

introruction khawf in(iran)-herat and mazaresharif and shirkhan bandar in (afghanistan)-dushanbe in (tajikistan)_(kirgizstan)-kashghar in(china) project railway network is under construction that it is as a significant corridor for revitalizing silk road corridor in the region .at the present there are three different gauge in the region central asia with 1,520 mm gauge and turkey-islamic repu...

15 صفحه اول

role of cultural iran in promotion of multilaieralism in central asia and caucasus

cultural iran is a scope that is more extended than the political territories of iran as a political unit. this concept means that cultural geography(mehdi moghanlo-1383-1) of iran is greater than its political geography which, according to history, has a long history extending west-east from kandahar to the euphrates and north-south from the persian gulf to the caucasus including transoxiana a...

15 صفحه اول

Diagnostic Reference Level of Computed Tomography Examinations and Need for Dose Optimization in Ondo State, Nigeria

Introduction: The present study was conducted to obtain State diagnostic reference levels (DRLs) of five routine computed tomography (CT) examinations from two CT centers in Ondo State and to identify factors responsible for dose variation and escalation in these CT centers. Material and Methods: Acquisition parameters and CT dose indices wer...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  267- 267

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023