Determination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]

Authors

  • Fereidoon Aflaki Nuclear Research Center, AOEI, Tehran, Iran
  • Gholamhossein Shirvani Nuclear Research Center, AOEI, Tehran, Iran
  • Maryam Salahinejad Nuclear Research Center, AOEI, Tehran, Iran
  • Nader Saemiyan Nuclear Research Center, AOEI, Tehran, Iran
Abstract:

Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suitable radiochemical purity was synthesized in nuclear research center of AEOI. Methods: In this report radiochemical and chemical purity of [14C] clozapine were determined by liquid scintillation and reversed phase-HPLC respectively. Separation of [14C] clozapine and its synthesized interface products was carried on C8 optimal column and UV detector at 254nm.The mobile phase consisted of acetonitril-buffered aqueous solution of sodium phosphate with a flow rate of 1ml/min. Results: Detection limit and analytical precision of RP-HPLC method were 0.01µg/ml and 1-3.4% respectively. The chemical purity of synthesized clozapine was >99%. For determination of activity and radiochemical purity, liquid scintillation spectrometer was used and counting was done by direct addition of samples to ACS (Amersham) solution. Specific activity of synthesized clozapine was 10µCi/mg and radiochemical purity of >99. % was achieved. Conclusion: By separation of [14C] clozapine and its synthesized intermediate products the represented methods, in addition to determination of total yield of reaction, it was possible to determine every step of reaction therefore; it was not nessaseray to use classical methods such as: distillation, liquid-liquid extraction, etc. If the HPLC instrument is equipped with radiochemical detector, simultaneous determination of radiochemical as well as chemical yields of products are possible.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

determination of chemical and radiochemical purity of [14c] clozapine by high performance liquid chromatography and liquid scintillation [persian]

introduction: the mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. the effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. to further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14c] clozapine with suitable ra...

full text

Vortex-Assisted Inverted Dispersive Liquid-Liquid Microextraction of Naproxen from Human Plasma and Its Determination by High-Performance Liquid Chromatography

Extraction and determination of naproxen from human plasma were performed using Vortex-Assisted Inverted Dispersive Liquid-Liquid MicroExtraction (VA−IDLLME) and High-Performance Liquid Chromatography (HPLC). The parameters affecting extraction recovery such as type and volume of extraction and disperser solvents, pH of sample solution, stirring rate, extraction time and salt addition were ...

full text

High-Performance Liquid Chromatography Determination of Methotrexate in Plasma

This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...

full text

High-Performance Liquid Chromatography Determination of Methotrexate in Plasma

This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...

full text

High Performance Liquid Chromatography Determination of Sertraline in Human

       An accurate and sensitive reversed-phase high-performance liquid chromatograph-ic method for determination of sertraline in human serum is described using 4-chloro-7-nitrobenzofurazan as pre-column derivatization agent. The drug and an internal standard (azithrimycin) were extracted from serum using a mixture of diethyl ether-chloroform and subjected to the pre-column derivatization with...

full text

Determination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography

Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 14  issue 1

pages  21- 27

publication date 2006-11-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023