Designing, Constructing and Installing a Local Exhaust Ventilation System to Minimize Welders\' Exposure to Welding Fumes
Authors
Abstract:
Background & Aims of the Study: Welder’s exposure to welding fumes can cause occupational diseases. The current study sought to examine exposure to welding fumes among welders who work in the repair shop of Sarcheshmeh Copper Complex and design a local exhaust ventilation system to control exposure to welding fumes. Materials & Methods: This applied analytical study was conducted in the summer of 2016 among welders working in the repair shop of Sarcheshmeh Copper Complex. The study comprised three phases; in the first one, welders’ exposure to welding fumes was assessed at the beginning of the study. After that, a local exhaust ventilation system was designed and installed in the aforementioned repair shop. In the final stage, welders’ exposure to welding fumes was assessed again after installation of the ventilation system. The procedure recommended by NIOSH (method number 7300) was used for individual sampling of welders. Results: Based on the obtained findings, before installing the ventilation system, welding technicians were exposed to 0.3 mg/m3 of copper fumes and 0.04 mg/m3 of chromium fumes. Journeyman welders were also exposed to 2.16 mg/m3 of manganese fumes, while stellar welders were exposed to 6.9 mg/m3 of iron fumes. In the light of these measurements, a local exhaust ventilation system was designed and installed. Subsequently, measurement of exposure to welding fumes showed a significant reduction. That is, welding technicians were exposed to 0.17 mg/m3 and 0.015 mg/m3 of copper and chromium fumes respectively. Additionally, journeyman welders were exposed to 0.86 mg/m3 of manganese fumes, whereas stellar welders were exposed to 4.3 mg/m3 of iron fumes. Conclusions: A comparison of standard limits of exposure to welding fumes and the results obtained from measurements in sampling stations before and after the installation of the local exhaust ventilation system reveals that this controlling measure was very effective in the repair shop of Sarcheshmeh Copper Complex.
similar resources
occupational exposure to welding fumes using different ventilation scenarios
welders may suffer from welding fumes generated during the process if the ventilation systems are improperly applied. the objective of the present work was to study the mitigation of air pollutants at welding stations, using different ventilation scenarios. four air pollutants including iron oxide, respirable dust, ozone, and carbon monoxide were measured during four different ventilation scena...
full textLocal exhaust ventilation for the control of welding fumes in the construction industry--a literature review.
Arc welding is a common unit operation in the construction industry, where frequent changes in location and welding position make it more difficult to control fume exposures than in industries where fixed locations are the norm. Welders may be exposed to a variety of toxic airborne contaminants including manganese (Mn) and hexavalent chromium (CrVI). Local exhaust ventilation (LEV) is a well-kn...
full textBronchial reactions to exposure to welding fumes.
OBJECTIVES To study the airway response and its mechanism to welding fumes in six welders with respiratory symptoms. METHODS Methacholine and welding challenge tests were carried out. The concentration of welding fumes during the exposure test was measured. On two subjects who developed bronchoconstricition to welding challenge, additional tests were carried out including prick, patch, and in...
full textConcentration Evaluation and Health Risk Assessment of Welders' Exposure to Total Fumes and Manganese during Welding at Metal Industry
Introduction and purpose: Risk assessment of toxic or hazardous chemicals enables industrial hygienists to make appropriate decisions regarding management provisions in a healthy workplace. Exposure to total fumes and manganese during welding can have harmful effects on welders’ health. Therefore, the present study was conducted in the metal industry to evaluate the concentration and determine ...
full textOccupational exposure to diesel exhaust fumes.
There is currently no OEL for diesel fumes in the UK. This study reports parallel measurements of airborne levels of diesel fume pollutants in nine distribution depots where diesel powered fork-lift trucks (FLTs) were in use. Correlations between individual pollutants are assessed as well as their spatial distribution. Samples were collected on board FLTs and at background positions at nine dis...
full textExploring the risk of welders’ exposure to the gases and metal fumes in a shipbuilding industry: a case study
Introduction: Risk identification and investigation is an appropriate and practical approach for the occupational health professionals. This paper aims to determine exposure to the gases and metal fumes and to perform risk analysis in three common types of welding activities in a shipbuilding industry. Material and method: This analytical cross-sectional study was conducted in a shipbuilding i...