Designing and developing an in-house CCD based optical CT scanner for gel dosimetry

Authors

  • Ahmad Mostaar Medical Physics and Biomedical Engineering Dept., Shahid Beheshti University of Medical sciences, Tehran, Iran
  • Mahmoud Shiri Medical Physics and Biomedical Engineering Dept., Shahid Beheshti University of Medical sciences, Tehran, Iran
  • Seyed Mohsen Sadat-Shahabi Medical Physics and Biomedical Engineering Dept., Shahid Beheshti University of Medical sciences, Tehran, Iran
  • Zahra Mansouri Medical Physics and Biomedical Engineering Dept., Shahid Beheshti University of Medical sciences, Tehran, Iran
Abstract:

Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI is gold standard readout instrument, but it is costly and time- consuming. Optical CT is faster and has very lower cost than other methods. The aim of this work is designing and developing an in-house fast CCD based optical computed tomography scanner to extract the 3D radiation dose distribution that recorded in irradiated PGDs. Materials and Methods: in this work we used an array of high power LEDs by 650nm wave length as broad beam light source and a CCD camera as large area detector. The image projections of test object that immersed in a water tank and its rotational movement were controlled by a stepper motor was obtained. Image reconstruction carried out in MATLAB environment with the Filtered back projection method.   Results: Reconstructed image quality is very promising. And it is comparable to results of the other works. Contrast to Noise Ratio (CNR) of reconstructed images without any filters in the back projection algorithm was 0.41. Using ramp filter with 0.2 cutoff frequency, gained a 1.1 in CNR and using Butterworth filter with cutoff frequency of 0.3 gained a CNR of 1.3. Increasing cutoff frequency for Butterworth filter will degrade noise properties of reconstructed image and CNR goes down to 0.82, which is comparable with similar works. Conclusion: Optical CT readout system is considered one of the best options for gel readings. If we can overcome the problems of reconstructed images with light rays, this system can be useful for fast and accurate readout of irradiated polymer gel dosimeters.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

design and construction of an optical computed tomography scanner for polymer gel dosimetry application

polymer gel dosimeter is the only accurate three dimensional (3d) dosimeter that can measure the absorbed dose distribution in a perfect 3d setting. gel dosimetry by using optical computed tomography (oct) has been promoted by several researches. in the current study, we designed and constructed a prototype oct system for gel dosimetry. first, the electrical system for optical scanning of the g...

full text

High resolution gel-dosimetry by optical-CT and MR scanning.

The increased intricacy of Intensity-Modulated-Radiation-Therapy (IMRT) delivery has created the need for a high-resolution 3D-dosimetry (three-dimensional) system capable of measuring and verifying the complex delivery. Present clinical methods are inadequate being restricted to single points (e.g., ion-chambers) or to 2D planes (e.g., film), and are labor intensive. In this paper we show that...

full text

Evaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners

Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...

full text

Development of a new laser-line and CCD based optical-CT scanner for the readout of 3D radiation dosimeters

We present initial results on the comparison of the dose readout from a three dimensional polymer gel dosimeter using two different optical-CT systems; i) a common wide field and a wide area detector optical-CT system and ii) a new ‘laser-line’ and wide area detector based optical-CT system. The findings presented herein highlight the advantage of the laser based over the wide field optical-CT ...

full text

Design and manufacturing a CTDI pediatric phantom for CT dosimetry using TLD, ion chambers, and gel dosimetry

Introduction: Nowadays, the demand for CT-scan is increased, and this issue has become a critical subject in radiation protection, because of the risk of cancer especially for children. The quality assurance of CT images is a necessary factor that can effect on children dose. The CT dose index is an important dosimetry index in CT-Scan dosimetry. The purpose of this study is t...

full text

development and implementation of an optimized control strategy for induction machine in an electric vehicle

in the area of automotive engineering there is a tendency to more electrification of power train. in this work control of an induction machine for the application of electric vehicle is investigated. through the changing operating point of the machine, adapting the rotor magnetization current seems to be useful to increase the machines efficiency. in the literature there are many approaches wh...

15 صفحه اول

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  6- 6

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023