Design and Fabrication of a Portable 1-DOF Robotic Device for Indentation Tests

Authors

  • Farshid Najafi School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
  • Masoud Moeinzadeh School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
  • Mojtaba Haghighi School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
  • Sheyda Davaria School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
Abstract:

There are many tactile devices for indentation examinations to measure mechanical properties of tissue. The purpose of this paper is to develop a portable indentation robotic device to show its usability for measuring the mechanical properties of a healthy abdominal tissue. These measurements will help to develop suitable mathematical models representing abdominal tissue. A 1-DOF portable robotic device has been designed to be placed on the patient’s body. The device presses sensor plate on the abdomen. Force and position sensors measure the indentation force and displacement, respectively. Due to tissue time-dependent behavior, linear viscoelastic models with three, five and seven parameters have been selected for mathematical modeling. Nonlinear Least Squares (NLS) method is adopted to fit viscoelastic models with experimental data obtained from stress relaxation tests. Using Finite Prediction Error (FPE) criterion, viscoelastic model with five parameters has been selected as the optimal model. The results of the present paper can be used in abdominal tissue simulators to facilitate teaching palpation examinations.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Design and Fabrication of a Microwave Weed Killer Device for Weed Control Applications

In this paper, the design and the results of a microwave radiation system for agriculture applications is discussed. The system is fabricated and successfully tested on weed seeds. The device, which uses a commercial 1 kW magentron, proved to be effective for preventing the germination control of popular weeds of Iran. Seven weed species were tested separately by using this system and then the ...

full text

Design and Fabrication of Ultralight High-Voltage Power Circuits for Flapping-Wing Robotic Insects

Flapping-wing robotic insects are small, highly maneuverable flying robots inspired by biologicalinsects and useful for a wide range of tasks, including exploration, environmental monitoring, searchand rescue, and surveillance. Recently, robotic insects driven by piezoelectric actuators have achievedthe important goal of taking off with external power; however, fully autonomous operation requir...

full text

A one-DOF freehand haptic device for robotic tele-echography.

Tele-echography may be an interesting alternative to conventional care when the medical expert is not close to the patient to be examined. In a system for tele-echography, medical expert proprioception and gesture feelings must be preserved to synchronize the ultrasound images with the motion made by the physician. It is why we develop a master-slave system for robotic tele-echography integrati...

full text

investigating the feasibility of a proposed model for geometric design of deployable arch structures

deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...

Fabrication of a Cell Fixation Device for Robotic Cell Microinjection

Automation of cell microinjection greatly reduces operational difficulty, but cell fixation remains a challenge. Here, we describe an innovative device that solves the fixation problem without single-cell operation. The microarray cylinder is designed with a polydimethylsiloxane (PDMS) material surface to control the contact force between cells and the material. Data show that when the injectio...

full text

Draft: Design and Fabrication of a Soft Robotic Direct Cardiac Compression Device

A direct cardiac compression (DCC) device is an active sleeve that is surgically placed around the heart to help the failing heart to pump without contacting blood. Soft robotic techniques enable fabrication of a conformable DCC device containing modular actuators oriented in a biomimetic manner that can restore the natural motion of the heart and provide tunable active assistance. In this pape...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 49  issue 1

pages  179- 188

publication date 2018-06-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023