Non-destructive detection and evaluation of invisible cracks in metal structures is an important matter in several critical environments including ground transportation, air transportation and power plants. In this paper, a high-Q near-field Microwave probe is designed and fabricated using defected ground structures for surface and subsurface crack detection in metal structures. For this purpose, several near-field probes with different DGSs are designed and probe with the highest quality factor is selected for subsurface detection. Experimental results show that the proposed probe is able accurately detect invisible crack of a size 1mm with at least 20dB magnitude and more than 300 degrees phase contrast. It has also been demonstrated that the proposed device can efficiently used for detection and imaging of small failure and crack in dielectric and metallic structures. Also, it is noted that if the probe dimensions scale down, spatial resolution for crack detection of size in micro and nanometer is achieved at millimeter waves.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

fabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

investigating the feasibility of a proposed model for geometric design of deployable arch structures

deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...

Plasmonic nanograting tip design for high power throughput near-field scanning aperture probe.

We design nanogratings consisting of concentric plasmonic resonance grooves on the metallic sidewalls of near-field scanning probe aperture to increase the power throughput without losing the imaging resolution. Nanograting tip design involves choosing the proper pitch length and the cut location of grooves. Four different nanograting designs are evaluated, as compared with standard single aper...

full text

simulation and design of electronic processing circuit for restaurants e-procurement system

the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...

15 صفحه اول

design, fabrication and field evaluation of a combine divider attachment for harvesting colza

colza (canola) is a crop with high rate of grain loss during harvesting. at harvest, semi-dried grains of canola’s pods are either opened or dropped due to mechanical impacts. therefore, lots of grains drop before entering combine head. another obstacle to successful harvest of canola is that ripe grain's pods are twisted together. this results in heavy grain loss at dividers of combine pi...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 7  issue 1

pages  1- 10

publication date 2018-06-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023