Design and Development of an Indigenous in-house Tissue-Equivalent Female Pelvic Phantom for Radiological Dosimetric Applications
Authors
Abstract:
Introduction: The present study is aimed to design and develop a tissue-equivalent pelvic phantom, mimicking the Indian female pelvic dimensions by means of locally available and cost-effective tissue substitutes having equivalent radiological properties. Materials and Methods: For the purpose of the study, the real female pelvic bones were embedded for preparation. Paraffin wax, Aloe-vera powder, purified borax, and sodium benzoate, were used to obtain the proper density and effective atomic number. A hollow three-dimensional outer surface and the internal organs moulds were fabricated using gypsona bandage. The internal organs moulds were filled with semi-solid paraffin wax mixture, stabilized, and then embedded with pelvic bones and internal organs at the right anatomical positions. The surface mould, along with the bones and internal organs, were stabilized in their position in the final form, and verified with computed tomography (CT). Results: The physical dimensions of the given female pelvic phantom were comparable with the mean dimensions of the Indian female pelvis. Furthermore this tissue-equivalent phantom was radiologically equivalent to the Indian human female pelvis in all respects. The CT numbers of the uterus, bladder, rectum, muscles, fats, bone, and cavities were 39.9, 30.5, 24.7, 34.6, -86.8, 578.6, and -220.9 HU, respectively. Furthermore, the relative electron densities of the muscle, fat and bones were 1.035, 0.913, and 0.779 in the phantom. Conclusion: The dimensions and physico-radiological properties of the tissue substitutes provided a good inhomogeneous female pelvic phantom differing in dimensions with imported pelvic phantoms. Therefore, this phantom can be used for radiological dosimetric applications.
similar resources
Dosimetric Study of an Indigenous and Heterogeneous Pelvic Phantom for Radiotherapy Quality Assurance
Introduction: In vitro dosimetric verification prior to patient treatment plays a key role in accurate and precision radiotherapy treatment delivery. Since the human body is a heterogeneous medium, the aim of this study was to design a heterogeneous pelvic phantom for radiotherapy quality assurance. Material and Methods: A pelvic phantom was ...
full textdevelopment and implementation of an optimized control strategy for induction machine in an electric vehicle
in the area of automotive engineering there is a tendency to more electrification of power train. in this work control of an induction machine for the application of electric vehicle is investigated. through the changing operating point of the machine, adapting the rotor magnetization current seems to be useful to increase the machines efficiency. in the literature there are many approaches wh...
15 صفحه اولDevelopment and Characterization of Synthetic Tissue- Equivalent Material for CT Imaging Applications
Introduction: The use of a simple tissue analog material in the fabrication of medical computed tomography (CT) imaging phantoms has great potential to help researchers. The purpose of the present study is to develop new gel tissue-equivalent materials and determine whether their CT numbers and relative electron densities vary in CT images obtained by scans at different energie...
full textDesign of homogeneous and heterogeneous human equivalent thorax phantom for tissue inhomogeneity dose correction using TLD and TPS measurements
Background: The purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the Treatment Planning Systems (TPS) calculated values for different lung treatment dosimetery. It is compared with Thermoluminescent Dosimeter (TLD) measurement. Materials and Methods: Homogeneous and heterogeneous tho...
full textDevelopment of Prototype Iranian male pelvic phantom for internal dosimetry
Introduction: Existing phantoms have been constructed based on Caucasian, non-Caucasian and race-specific datasets. According to previous studies made efforts to present Korean- specific phantoms and Chinese female phantom based on CVH dataset due to compare the resulting internal dosimetry with the Caucasian based data showed possible racial difference in human anatomy between ...
full textConstruction of an Equivalent Chest Homogeneous Phantom for Evaluation of Image Quality in Pediatric Radiography
Introduction: The purpose of this study is to build homogeneous equivalent phantom chest in order to provide the necessary ability for checking the image quality in radiographic tests in four age groups of children in terms of the most recent age group categorization ICRP103. This phantom provides the features of weakness and discrepancies similar to body and can be consi...
full textMy Resources
Journal title
volume 15 issue 3
pages 200- 205
publication date 2018-07-01
By following a journal you will be notified via email when a new issue of this journal is published.
Hosted on Doprax cloud platform doprax.com
copyright © 2015-2023